Dehumidifying mode
e dehumidifying mode is illustrated as follows:
Dehumidifying area I: Operation at the frequency in the range (30–60Hz) according to Dt (Tindoor ambient-Tset).
Dehumidifying area II: The compressor stops for 5 minutes and operators for 5 minutes at the lowest frequency.
Dehumidifying area III: The compressor stops.
Dt(°F) f(Hz)
32 30
33 30
34 40
35 50
36 60
Figure 304
Figure 305
62˚F