EasyManua.ls Logo

Friedrich FPHMR18A3A User Manual

Friedrich FPHMR18A3A
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1 PB
Service/ Parts Manual
Floating Air Pro
Multi-Zone
9261402_00
Type Model
Outdoor Condensor FPHMR18A3A
Outdoor Condensor FPHMR24A3A
Outdoor Condensor FPHMR36A3A
Indoor Wall Mount FPMW07A3A
Indoor Cassette FPHFC09A3A
Indoor Cassette FPHFC12A3A
Indoor Cassette FPHFC18A3A
Indoor Cassette FPHFC24A3A
Indoor Ducted FPHFD09A3A
Indoor Ducted FPHFD12A3A
Indoor Ducted FPHFD18A3A
Indoor Ducted FPHFD24A3A
Indoor Accessory FPCG0912
Indoor Accessory FPWC1
Indoor Accessory FPCG182436

Table of Contents

Other manuals for Friedrich FPHMR18A3A

Question and Answer IconNeed help?

Do you have a question about the Friedrich FPHMR18A3A and is the answer not in the manual?

Friedrich FPHMR18A3A Specifications

General IconGeneral
BrandFriedrich
Model NumberFPHMR18A3A
Energy Efficiency Ratio (EER)12.0
RefrigerantR-410A
Cooling Capacity18, 000 BTU
Operating ModesCool, Heat, Fan, Auto

Summary

Introduction

Important Safety Information

Provides crucial safety guidelines for installation and repair personnel.

Electrical Hazards

Lists electrical safety procedures like shutting off power and proper grounding.

Do Not Operate Equipment During Active Stages of Construction

Warns against operating equipment during construction to avoid premature failure.

Personal Injury Or Death Hazards

Warns against disabling safety devices, which can lead to severe injury or death.

Model Identification Guide

Explains the model number breakdown for identification purposes.

Product Appearance

Illustrates physical aspects of indoor units (Duct, Cassette) and outdoor units.

Specifications

Product Specifications Multi-Zone Wall-Mounted

Details performance ratings, electrical data, and dimensions for wall-mounted units.

Product Specifications Multi-Zone-Cassette

Details performance ratings, electrical data, and dimensions for cassette units.

Product Specifications Multi-Zone Concealed Ducted

Provides performance ratings, electrical data, and dimensions for concealed ducted units.

Product Specifications 18K, 24k and 36k Outdoor Condensor

Details performance ratings, operating ranges, and electrical data for outdoor units.

Product Dimensions: Wall Mounted Indoor Units

Illustrates dimensions and provides a table for wall-mounted indoor units.

Product Dimensions: 9k, 12k, and 18k Ducted Indoor Units

Provides dimensional diagrams and a table for ducted indoor units (9k, 12k, 18k).

Non-Ducted Fphmr18a3a Cooling Capacity

Presents cooling capacity data (TC, SHC, PI) for Non-Ducted Fphmr18a3a.

Ducted Fphmr18a3a Cooling Capacity

Presents cooling capacity data (TC, SHC, PI) for Ducted Fphmr18a3a.

Mixed Fphmr18a3a Cooling Capacity

Presents cooling capacity data (TC, SHC, PI) for Mixed Fphmr18a3a.

Non-Ducted Fphmr36a3a Cooling Capacity

Presents cooling capacity data (TC, SHC, PI) for Non-Ducted Fphmr36a3a.

Ducted Fphmr36a3a Heating Capacity

Presents heating capacity data (TC, PI) for Ducted Fphmr36a3a.

Mixed Fphmr36a3a Heating Capacity

Presents heating capacity data (TC, PI) for Mixed Fphmr36a3a.

Single Zone Cassette Cooling Capacity

Presents cooling capacity data for Single Zone Cassette units.

Refrigerant Cycle 24k and 36k Outdoor Units

Illustrates the refrigerant cycle for 24k and 36k outdoor units.

Electrical Requirements 24k and 36k Outdoor Units

Details electrical wiring diagrams and recommended wire sizes for 24k and 36k outdoor units.

Correction Factors

Piping Length Correction Factor

Explains how to calculate correction factors based on piping length and height difference.

Correction Factors According to Defrosting Operation

Explains how heating capacity is corrected considering frost and defrosting operation.

Operation

Display Panel

Identifies and describes the function of indicators and buttons on the display panel.

Remote Controller Operation and Function

Details the functions and buttons of the remote controller.

Indoor Unit Operation

Explains the operation of LEDs, error codes, and manual controls for the indoor unit.

Sleep Function

Explains the operation of Sleep mode in Cooling, Heating, and Dry modes.

Auto Mode (SMART)

Explains how the system automatically switches modes based on room temperature.

Defrost

Details the conditions for activating and ending the defrost operation.

Installation

Outdoor Units Piping Connections

Details piping connections to the outdoor unit and provides a torque table for tightening.

24 and 36k Outdoor Units Piping Work and Refrigerant Charge

Covers piping work, refrigerant charge, and maximum allowed length/height for 24k and 36k units.

Leak Check, Evacuation, and Charging (Triple Evacuation)

Details the steps for nitrogen pressure test, vacuum tests, and system charging.

Installation Checklist

Lists items to check after installation and their potential malfunctions.

Operation Test

Details system checks, indoor unit checks, and outdoor unit checks for test operation.

Fresh Air Intake

Explains how to install the fresh air intake for Duct and Cassette units.

Maintenance

Front Panel and Shell Maintenance

Provides step-by-step instructions for cleaning the front panel and shell.

Air Filter Maintenance

Details steps for cleaning and reinstalling the air filter.

Front Shell, Air Duct and Fan Maintenance

Guides on removing components for cleaning the front shell, air duct, and fan.

R-410A Sealed System Repair

Service Valves Appearance

Illustrates the appearance and identifies key parts of 2-way and 3-way service valves.

Pumping Down (Transfering)

Details the valve positions for pumping down during refrigerant transfer.

Evacuation (Servicing)

Explains valve positions and actions for evacuation during servicing.

Gas Charging (After Repair)

Details the procedure for charging the system with refrigerant, including precautions.

Replace 24k Outdoor unit Compressor and Motor

Guides through the steps for removing and replacing the compressor and motor in a 24k outdoor unit.

Replace 9k, 12k, and18k Cassette Fan Motor

Details the steps for replacing the fan motor in 9k, 12k, and 18k cassette units.

Replace 9k, 12k, and18k Cassette Condensate Pump

Details the removal and installation steps for the condensate pump.

Components Testing

Resistance Table Of Indoor Coil And Indoor Room Sensor

Lists resistance values for indoor coils and room sensors at various temperatures.

Resistance Table Of Outdoor Compressor Temperature Sensor

Lists resistance values for outdoor compressor temperature sensors at various temperatures.

Compressor Testing

Explains how to test compressor winding resistance and common signs of faulty compressors.

Fan Motor Testing

Details testing the resistance of the main winding and DC voltage test for fan motors.

Field Settings (ESP Setting) Duct Type Only

Explains how to adjust static pressure settings for duct type units using the remote controller.

Field Settings (Indoor Unit Parameter Revision)

Guides on connecting the wired controller and changing system parameters via the LCD.

Field Settings (Running Parameter Query)

Explains how to check outdoor running parameters using the 7-segment display and its buttons.

Troubleshooting

Test the Jumper Terminals

Explains how to test jumper terminals on the control board to check external unit operation.

Protection Circuit Fault Isolation

Details voltage and current protection conditions, actions, and release criteria.

Compressor Fault Isolation

Explains how to judge connecting terminals, measure resistance, and notes on compressor handling.

Electrical Communication Fault Isolation

Details steps to determine wiring correctness, loose connections, and voltage fluctuations.

Fault Codes

Describes fault codes indicated by LED lamps on the display panel and wiring.

Indoor Fault Code

Provides a table of indoor unit fault codes, possible reasons, and how to deal with them.

18K, 24k and 36k Outdoor Fault Codes

Explains how fault codes are displayed on the control board and drive board.

Wiring Diagrams

7k Wall Units Wiring

Shows the electrical wiring diagram for 7k wall-mounted units.

Ducted Indoor Units Wiring

Provides electrical wiring diagrams and a table for components in ducted units.

9k-36k Indoor Cassette Units Wiring

Provides electrical wiring diagrams and a table for components in cassette units.

24k Outdoor Units Wiring

Shows the electric wiring diagram for 24k outdoor units.

36k Outdoor Units Wiring

Shows the electric wiring diagram for 36k outdoor units.

Parts Catalog

18K Outdoor Condensor Parts

Illustrates and labels components of the 18K outdoor condenser.

18K Outdoor Condensor Parts List

Lists part numbers, descriptions, and used on models for the 18K outdoor condenser.

24K Outdoor Condensor Parts

Illustrates and labels components of the 24K outdoor condenser.

36K Outdoor Condensor Parts

Illustrates and labels components of the 36K outdoor condenser.

36K Outdoor Condensor Parts List

Lists part numbers, descriptions, and used on models for the 36K outdoor condenser.

7k Wall Mounted Indoor Unit Parts

Illustrates and labels components of the 7k wall-mounted indoor unit.

7k Wall Mounted Indoor Unit Parts List

Lists part numbers, descriptions, and used on models for the 7k wall-mounted indoor unit.

9K, 12K Indoor Cassette Parts

Illustrates and labels components of the 9K and 12K indoor cassette units.

9K, 12K Indoor Cassette Parts List

Lists part numbers, descriptions, and used on models for the 9K and 12K indoor cassette units.

24K Indoor Cassette Parts

Illustrates and labels components of the 24K indoor cassette unit.

24K Indoor Cassette Parts List

Lists part numbers, descriptions, and used on models for the 24K indoor cassette unit.

9K, 12K, Ducted Indoor Parts

Illustrates and labels components of the 9K, 12K ducted indoor units.

9K, 12K Ducted Indoor Parts List

Lists part numbers, descriptions, and used on models for 9K, 12K ducted indoor units.

18K Ducted Indoor Parts

Illustrates and labels components of the 18K ducted indoor unit.

18K Ducted Indoor Parts List

Lists part numbers, descriptions, and used on models for the 18K ducted indoor unit.

Appendix

Appendix 1: Reference Sheet of Celsius and Fahrenheit

Offers a reference sheet for converting between Celsius and Fahrenheit temperatures.

Appendix 2: Pipe Expanding Method

Details the method for expanding pipes, including cutting, burr removal, and insulation.

Accessories

Controller

Details the wired wall controller option for Floating Air Premier and Pro models.

Ceiling Cassette Grilles (Required Accessory)

Lists required decorative grilles for ceiling cassette models.

Limited Warranty

Five Year Warranty

Details the five-year warranty for Friedrich products, excluding labor costs.

Compressor Warranty

Details the seven-year compressor warranty, excluding labor for replacement.

Warranty Service and Notices

Advises users on obtaining service, exclusions, and state-specific warranty rights.

Limited Warranty Exclusions and Limitations

Lists damages not covered by warranty and limitations on implied warranties.

Customer Satisfaction and Quality Assurance

Friedrich Authorized Parts Depots

Lists contact information for authorized parts depots.

Technical Support Contact Information

Friedrich Air Conditioning Co. Contact

Provides contact information for Friedrich Air Conditioning Co.

Related product manuals