Service/ Parts Manual
Floating Air Pro-Premiere
Single Zone
96261401_01
Model Indoor Unit Outdoor Unit Voltage BTU
FPHW091 FPHSW09A1A FPHSR09A1A 115 9k
FPHW091A FPHSW09A1B FPHSR09A1A 115 9k WiFi
FPHW093 FPHFW09A3A FPHSR09A3A 208/230 9k
FPHW093A FPHFW09A3B FPHSR09A3A 208/230 9k WiFi
FRHW093 FRHSW09A3A FRHSR09A3A 208/230 9k
FRHW093A FRHSW09A3B FRHSR09A3A 208/230 9k WiFi
FPHW121 FPHSW12A1A FPHSR12A1A 115 12k
FPHW121A FPHSW12A1B FPHSR12A1A 115 12k WiFi
FPHW123 FPHFW12A3A FPHSR12A3A 208/230 12k
FPHW123A FPHFW12A3B FPHSR12A3A 208/230 12k WiFi
FRHW123 FRHSW12A3A FRHSR12A3A 208/230 12k
FRHW123A FRHSW12A3B FRHSR12A3A 208/230 12k WiFi
FPHW183 FPHFW18A3A FPHSR18A3A 208/230 18k
FPHW183A FPHFW18A3B FPHSR18A3A 208/230 18k WiFi
FPHW243 FPHFW24A3A FPHSR24A3A 208/230 24k
FPHW243A FPHFW24A3B FPHSR24A3A 208/230 24k WiFi
FPHW363 FPHSW36A3A FPHSR36A3A 208/230 36k
FPHW363A FPHSW36A3B FPHSR36A3A 208/230 36k WiFi
FPHW363B FPHSW36A3C FPHSR36A3B 208/230 36k WiFi

Table of Contents

Other manuals for Friedrich FPHW091

Questions and Answers

  • A
    Ashley WilliamsSep 19, 2025
    How to resolve communication trouble between outdoor unit and driver in Friedrich FPHW091 Air Conditioner?
    • S
      sheri58Sep 22, 2025
      If your Friedrich Air Conditioner is experiencing communication trouble between the outdoor unit and the driver, start by checking the connection wires to ensure they are not loose. If the wires are secure, the outdoor board or drive board may have failed and require replacement.
  • K
    Kimberly MosesAug 25, 2025
    What to do about communication trouble between my Friedrich FPHW091's outdoor unit and driver?
    • J
      James HallAug 25, 2025
      Communication trouble between the outdoor unit and driver of your Friedrich Air Conditioner can be due to: * Loose connection wires; secure any loose connection wires. * A failed outdoor board or drive board; replace the outdoor board or drive board.
  • Z
    Zachary NguyenAug 25, 2025
    How to fix communication failure between indoor and outdoor unit of Friedrich FPHW091?
    • J
      Jesse FoleyAug 26, 2025
      A communication failure between the indoor and outdoor units of your Friedrich Air Conditioner can occur for several reasons: * The communication cable connector may be loose; ensure it is securely connected. * The connection between the filter board and the terminal might be incorrect or loose; verify the connection is correct and secure. * The communication cable itself might be faulty and need replacement. * The connection between the filter board and the outdoor control board might be incorrect or loose; verify the connection is correct and secure. * A failure in the indoor control board, PFC board, power board, or outdoor control board could also be the cause, requiring replacement of the respective board.
  • S
    Sarah JohnsonAug 27, 2025
    What to do if my Friedrich FPHW091 Air Conditioner has current overload protection?
    • C
      Colton ReedAug 27, 2025
      If your Friedrich Air Conditioner is experiencing current overload protection, it could be due to: * The fan motor running abnormally, in which case you should check and repair the fan motor. * Dirty condenser and evaporator coils, so you should clean them. * Abnormal air inlet and outlet; ensure that they are unobstructed.
  • D
    davidfreySep 23, 2025
    What causes anti-freeze or overload protection in my Friedrich FPHW091 indoor unit?
    • M
      Michelle NguyenSep 23, 2025
      If your Friedrich Air Conditioner is experiencing 'Anti-freeze protection with cooling or overload protection with heating in indoor unit', start by checking the indoor coil temperature sensor connector to ensure it's properly connected. If the connector is fine, the indoor coil temperature sensor itself may have failed and need replacement. If the problem persists, the indoor control board might be faulty and require replacement. Additionally, consider checking the refrigerant system for any abnormalities.
  • J
    jeffreyliSep 23, 2025
    What to do if my Friedrich Air Conditioner shows outdoor EEPROM faulted?
    • V
      victor93Sep 23, 2025
      If your Friedrich Air Conditioner displays an 'Outdoor EEPROM faulted' error, first check if the EEPROM chip is loose. If it is, ensure it's properly secured. Also, verify that the EEPROM chip is inserted in the correct direction. If the chip is correctly oriented and secured, the EEPROM chip itself may have failed and need to be replaced.
  • S
    Sara WoodSep 10, 2025
    What to do if Friedrich Air Conditioner shows maximum current protection?
    • K
      Kristin RyanSep 10, 2025
      If your Friedrich Air Conditioner is showing maximum current protection, it could be due to a short circuit. This could be in the outdoor control board, the drive board, or other components. It is suggested to replace the outdoor control board or drive board if they are short-circuited. Inspect and replace any other short-circuited components.
  • X
    xjonesSep 12, 2025
    Why does my Friedrich Air Conditioner have current overload protection?
    • J
      Jessica HayesSep 12, 2025
      If your Friedrich Air Conditioner is showing signs of current overload protection, it could be due to a few reasons. Start by inspecting the fan motor to ensure it's running correctly. Next, check the condenser and evaporator for dirt and clean them if necessary. Lastly, make sure the air inlet and outlet are not blocked or otherwise abnormal.
  • N
    Nicole BullockSep 3, 2025
    What to do if the outdoor coil temperature sensor faulted on my Friedrich Air Conditioner?
    • P
      pmarquezSep 3, 2025
      If the outdoor coil temperature sensor faulted on your Friedrich Air Conditioner, it could be due to: * A loose outdoor coil sensor connector, which should be secured. * A failed outdoor coil temperature sensor, which should be replaced. * A failed outdoor control board, which should be replaced.
  • A
    Andrew DeleonSep 1, 2025
    What causes a compressor drive fault in my Friedrich FPHW091?
    • C
      Carl LuceroSep 1, 2025
      A compressor drive fault in your Friedrich Air Conditioner can be caused by: * A failed outdoor drive board, which would need to be replaced. * A failed compressor, which would also need replacement. * A failed outdoor control board, requiring replacement.