EasyManua.ls Logo

Friedrich FPHFR18A3A User Manual

Friedrich FPHFR18A3A
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1 PB
Service/ Parts Manual
Floating Air Pro Single- Zone
Cassette and Ducted
9261402_00
Type Model
Outdoor Condensor FPHFR9A3A
Outdoor Condensor FPHFR12A3A
Outdoor Condensor FPHFR18A3A
Outdoor Condensor FPHFR24A3A
Outdoor Condensor FPHFR36A3A
Indoor Cassette FPHFC09A3A
Indoor Cassette FPHFC12A3A
Indoor Cassette FPHFC18A3A
Indoor Cassette FPHFC24A3A
Indoor Cassette FPHFC36A3A
Indoor Ducted FPHFD09A3A
Indoor Ducted FPHFD12A3A
Indoor Ducted FPHFD18A3A
Indoor Ducted FPHFD24A3A
Indoor Ducted FPHFD36A3A
Indoor Accessory FPCG0912
Indoor Accessory FPWC1
Indoor Accessory FPCG182436

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Friedrich FPHFR18A3A and is the answer not in the manual?

Friedrich FPHFR18A3A Specifications

General IconGeneral
BrandFriedrich
ModelFPHFR18A3A
CategoryAir Conditioner
LanguageEnglish

Summary

Floating Air Pro Single-Zone Cassette and Ducted

INTRODUCTION

Important Safety Information

Crucial safety guidelines for installation, operation, and maintenance.

Personal Injury Or Death Hazards

Details potential hazards causing personal injury or death, with safety first advice.

ELECTRICAL HAZARDS

Specific warnings and precautions related to electrical hazards during service.

SPECIFICATIONS

Product Specifications Single-Zone-Cassette

Detailed specifications for single-zone cassette type air conditioning units.

Product Specifications Single-Zone Concealed Ducted

Detailed specifications for single-zone concealed ducted type air conditioning units.

Capacity Characteristics Chart Single Zone Ducted

Charts detailing cooling and heating capacities for ducted units based on various conditions.

Refrigerant Cycle 9-18k Outdoor Units

Diagram and component list for the refrigerant cycle of 9-18k outdoor units.

CORRECTION FACTORS

Height Correctiion Factors

Factors to adjust capacity based on vertical and horizontal piping distances.

Piping Length Factor Chart

Chart detailing correction factors based on piping length for height differences.

OPERATION

Outdoor Unit Control Mode

Control functions for outdoor units including protection mechanisms.

INSTALLATION

Outdoor Units

Installation steps for outdoor units, including piping and torque table.

Leak Check, Evacuation, and Charging (Triple Evacuation)

Detailed steps for leak checking, evacuating, and charging the refrigerant system.

Checklist

A checklist of items to verify after installation to prevent malfunctions.

Operation Test

Procedures for testing the unit's operation after installation and safety checks.

R-410A SEALED SYSTEM REPAIR

Pumping Down

Procedure for pumping down the refrigerant system before servicing.

Replace 9-18k Outdoor unit Compressor and Motor

Detailed steps for replacing the compressor and motor in 9-18k outdoor units.

COMPONENTS TESTING

Check Refrigerant System

Procedures for checking the refrigerant system flow and pressure.

TROUBLESHOOTING

Troubleshooting according to fault codes

How to interpret and address fault codes indicated on the display panel or remote.

Outdoor Unit Fault Code

A list of outdoor unit fault codes, their descriptions, possible causes, and how to deal with them.

Indoor Unit Fault Codes

A list of indoor unit fault codes, their descriptions, possible causes, and solutions.

Drive fault code (3.0/3.5HP)

Troubleshooting guide for drive fault codes in 3.0/3.5HP units.

WIRING DIAGRAMS

PARTS CATALOG

Related product manuals