- 6 -
Only for training and service purposes
1.2 Inspections after Repair
Check to see if the parts are mounted correctly and wires are connected.
Improper installation and connections can cause an electric shock or an injury.
Check the installation platform or frame has corroded. Corroded installation plat-
form or frame can cause the unit to fall, resulting in injury.
Be sure to check the earth wire is correctly connected.
After the work has finished, be sure to do an insulation test to check that
resis-tance is 2[Mohm] or more between the charge section and the non-charge
metal section (Earth position). If the resistance value is low, a disaster such as a
leak or electric shock is caused at user’s side.
Check the drainage of the indoor unit after the repair. If drainage is faulty
water may enter the room and wet floor.
Check to see if the power cable is not dirty or loose. If the plug is dusty or
loose it can cause an electrical shock or fire.
Do not use a spliced power cable or extension cable, or share the same power
outlet with other electrical appliances. otherwise, it can cause an electrical shock,
excessive heat generation or fire.
Do not insert hands or other objects through the air inlet or outlet while the prod-
uct is operating. There are sharp and moving parts that could cause personal
injury.
Do not block the inlet or outlet of air flow. It may cause product failure

Table of Contents

Other manuals for Friedrich MC24Y3J

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Friedrich MC24Y3J and is the answer not in the manual?

Friedrich MC24Y3J Specifications

General IconGeneral
BrandFriedrich
ModelMC24Y3J
CategoryAir Conditioner
LanguageEnglish

Related product manuals