STEP 6. Inspect the unit before inserting it into the sleeve. The fan
VKRXOGEHPDQXDOO\URWDWHGWRLQVXUHWKDWWKH\WXUQIUHHO\%H
sure the electrical cord will be out of the way when inserting
the unit into the sleeve.
NOTE: )RU\RXUVDIHW\'2127SOXJWKHHOHFWULFDOFRUGLQWRDQHOHFWULFDO
outlet until installation is complete.
STEP 7. ,IWKHXQLWFKHFNVRXW2.LWLVUHDG\WREHSODFHGLQWRSRVLWLRQ
on bottom rails of the cabinet and pushed into place.
NOTE: 'RDOOOLIWLQJRIWKHXQLWE\WKHERWWRPSDQRQO\DQGZLWKDVVLVWDQFH
or help as necessary (See Figure 14).
STEP 8. The chassis must be pulled out slightly, so that there is a gap
RIEHWZHHQWKHXQLWDQGVKHOO6HH)LJXUH
STEP 9. ,QVWDOOWKHZKLWHFKDVVLVVHDOJDVNHWLWHPSDJHDQG
WKHJUD\ZLQGRZVHDOJDVNHWLWHP &DUHIXOO\LQVHUW WKH
ZKLWHJDVNHWLWHPEHWZHHQWKHFKDVVLVDQGWKHFDELQHW
starting at either bottom corner and go up the side, across
the top and down the opposite side. Insert the gray gasket
LWHP EHWZHHQ WKHZLQGRZ VDVKHV DV VKRZQ LQ)LJXUH
16. If chassis seal gasket is not installed, the operation of the
XQLWZLOOEHQHJDWLYHO\DIIHFWHG$OVRWKHRSHUDWLRQQRLVHDQG
RXWVLGHQRLVHZLOOEHDPSOL¿HG
STEP 10. Hold the decorative front as shown in Figure 17. Insert the two
WDEVRIWKH'HFRUDWLYH)URQW3DQHOLQWRWKHVORWVLQWKHWRSRI
the cabinet and lower the bottom of the decorative front to the
ERWWRPRIWKHFDELQHW5RXWHWKHHOHFWULFDOFRUGWRWKHULJKWRU
left side of the bottom of the cabinet as required by the location
of the electrical wall outlet. Use the notches provided at the
ERWWRPRIWKH'HFRUDWLYH)URQW3DQHOIRUURXWLQJWKHHOHFWULFDO
FRUGRXWRIWKHXQLW$WWDFKWKHGHFRUDWLYHIURQWWRWKHFDELQHW
ZLWKWZR1R[ò3KLOOLSVKHDGVFUHZVLWHPSDJH
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
FRR087
SCREW , 1/2 PHILLIPS HEAD
(SEE ILLUSTRATION,
ITEM #2, P AGE 22)
SCREW , 1 1/4 PHILLIPS HEAD
(SEE ILLUSTRATION,
ITEM #4, P AGE 22)
SCREW , #8 x 7/8 HEX HEAD
(SEE ILLUSTRATION,
ITEM #3, P AGE 22)
WINDOW STOOL
SHELL SUPPORT CHANNEL
WINDOW SASH
CABINET
SILL
CHANNEL
SECTION A-A
A
A
STEP 11. CIRCUIT PROTECTION - If the air conditioner is circuit
SURWHFWHGE\DIXVHXVHD7,0('(/$<IXVHRU+$&5W\SH
&LUFXLW%UHDNHUGXHWRPRPHQWDU\KLJKFXUUHQWGHPDQGZKHQ
\RXUDLUFRQGLWLRQHULVVWDUWHG%HIRUHRSHUDWLQJ\RXUXQLWYHULI\
the ampere rating of the time-delay fuse or circuit breaker
which protects your unit. The ampere rating of the time-delay
IXVHRUFLUFXLWEUHDNHUVKDOOEHDPSV5HIHUWR2SHUDWLRQ
section for more detailed operating instructions.
NOTE: 5HPRYHWDSHDQGYHULI\¿OWHULVLQWDFWDVSHU¿OWHULQVWUXFWLRQV
found inside door.
Figure 15