33
&203/$,17 &$86( 62/87,21
8QLW'RHV1RW&RRO+HDW5RRP6XI¿FLHQWO\2U
&\FOHV2Q$QG2II7RR)UHTXHQWO\FRQWLQXHG
Ɣ The outside temperature is below
)&
Ɣ 'RQRWWU\WRRSHUDWH\RXUDLUFRQGLWLRQHULQWKH
cooling mode when the outside temperature is
EHORZ)&7KHXQLWZLOOQRWFRROSURSHUO\
and the unit may be damaged.
Ɣ The digital control is set to fan
cycling mode.
Ɣ Since the fan does not circulate the room air
continuously at this setting, the room air does not
PL[DVZHOODQGKRWRUFROGVSRWVPD\UHVXOW
Using the continuous fan setting is recommended
to obtain optimum comfort levels.
Ɣ 7KHDLUFRQGLWLRQHUKDVLQVXI¿FLHQW
cooling capacity to match the heat
gain of the room.
Ɣ &KHFNWKHFRROLQJFDSDFLW\RI\RXUXQLWWRHQVXUHLW
LVSURSHUO\VL]HGIRUWKHURRPLQZKLFKLWLVLQVWDOOHG
5RRPDLUFRQGLWLRQHUVDUHQRWGHVLJQHGWRFRRO
multiple rooms.
Ɣ 7KHDLUFRQGLWLRQHUKDVLQVXI¿FLHQW
heating capacity to match the heat
loss of the room.
Ɣ &KHFNWKHKHDWLQJFDSDFLW\RI\RXUXQLW$LU
FRQGLWLRQHUVDUHVL]HGWRPHHWWKHFRROLQJORDG
DQGKHDWHUVL]HLVWKHQVHOHFWHGWRPHHWWKH
KHDWLQJORDG,QH[WUHPHQRUWKHUQFOLPDWHVURRP
air conditioners may not be able to be used as a
primary source of heat.
8QLW5XQV7RR0XFK
Ɣ 7KLVPD\EHGXHWRDQH[FHVVLYH
heat load in the room.
Ɣ If there are heat producing appliances in use in the
room, or if the room is heavily occupied, the unit will
need to run longer to remove the additional heat.
Ɣ It may also be due to an improperly
VL]HGXQLW
Ɣ %HVXUHWRXVHH[KDXVWYHQWIDQVZKLOHFRRNLQJ
or bathing and, if possible, try not to use heat
producing appliances during the hottest part of the
day.
Ɣ This may be normal for higher
HI¿FLHQF\((5DLUFRQGLWLRQHUV
Ɣ 7KHXVHRIKLJKHUHI¿FLHQF\FRPSRQHQWVLQ\RXU
new air conditioner may result in the unit running
longer than you feel it should. This may be more
DSSDUHQWLILWUHSODFHGDQROGHUOHVVHI¿FLHQW
model. The actual energy usage, however, will be
VLJQL¿FDQWO\OHVVZKHQFRPSDUHGWRROGHUPRGHOV
Ɣ <RXPD\QRWLFHWKDWWKHGLVFKDUJH
air temperature of your new air
conditioner may not seem as cold
as you may be accustomed to from
older units. This does not, however,
indicate a reduction in the cooling
capacity of the unit.
Ɣ 7KHHQHUJ\HI¿FLHQF\UDWLR((5DQGFRROLQJ
FDSDFLW\UDWLQJ%WXKOLVWHGRQWKHXQLW¶VUDWLQJ
SODWHDUHERWKDJHQF\FHUWL¿HG