A. Remove the Power Pack from the Robomow.
B. Remove the cover, as outlined in section 4.2.1 and expose the power pack contacts, as
illustrated in Figure 4.2.8.2.
C. Disconnect the damaged power pack contact from its lead and replace it with a new one.
Ensure the leads are connected correctly – red wire on LH contact, black on RH.
D. Return the cover as outlined in section 4.2.2.
E. Test the functionality of the Robomow by replacing the Power Pack and observing that the
unit “wakes up”.
F. Complete the General Test as outlined in section 5.1.