Frigomatic Milano Manual v1 PAGE 5
The vent openings should be positioned in such a way that immediate recirculation of
heated air does not occur. Recirculation of heated air causes it to become progressively
warmer reducing the condenser capacity, lowering the efficiency of the refrigeration plant,
and resulting in an increased power consumption and/or loss of cooling capacity.
Do not install the unit free standing in a small compartment and take care that where the
discharge air enters a small compartment that it cannot immediately reticulate back
through an outlet in the same bulkhead. Avoid also using air which is preheated as a result
of being drawn from, for instance, the engine compartment.
2.2 - GRILL
If the hole and therefore the finned condenser is in a position exposed to physical damage
it should be protected by a grill having at least the same cross-section of the condenser.
We recommend using our grill E250115 which allows a sufficient air flow and a good
protection to the unit.