Frigomatic Milano Manual v1 PAGE 9
CHAPTER 4
FRIGOMATIC MILANO PUMP WATER COOLED
12/24V DC compressor
Cupro nickel sea water heat exchanger with built in over heat switch
Pre-charged with R134a refrigerant with resealing male and female quick couplings to
connect to the evaporator.
Supplied as standard with both high and low pressure service valves.
4.1 - POSITION
When deciding on the location of the compressor please consider the following:
A.- The compressor must be mounted horizontally on its base.
Fix with the pre-drilled holes in the stainless steel base.
Pay attention to leave enough space for the evaporator and sea water connections and
that there is good access to the electrical connections
It can be safely angled up to 30 degrees so no problem for sailing boats
Note: Bulkhead mounting bracket also available – contact sales@penguinfrigo.co.uk for
details
B.- The length of the connecting pipe is 2.8mt (8ft) without using the optional extension
pipes contact sales@penguinfrigo.co.uk for details
4.2 - SEA WATER PUMP
The pump we supply is self-priming, but we recommend:
Installation
The pump is mounted as low in the boat as possible – ideally below the waterline.
Use wire reinforced hose
Ensure the pipe run from the intake and strainer to the pump is as direct as possible and
the pipe run from the pump to the condenser is as direct as possible
The outlet should be just above the waterline so the flow can be confirmed
Sea Water Strainer
You must have a good intake strainer (120 Mesh) to protect the pump, pipework and
condenser from sea water growth and organisms. Frigoboat part number A091508
contact
sales@penguinfrigo.co.uk for details.
Water flow requirement is 4-5 litres per minute 9 (1 gal/min)