EasyManua.ls Logo

Frigomat G20 - Condensation, Temperature, and Humidity Requirements; Critical Operational Safety

Frigomat G20
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 - ENGLISH
2. Condensation pressure (water models
only).
With the machine in production mode, after a
few seconds condensation water must come
out of the drain pipe at a temperature of about
35°C. If this is not the case, the pressure switch
valve shown in the figure must be adjusted.
Three-phase machines are powered with three-
phase + neutral lines: be careful never to
connect the phase lines with neutral.
FRIGOMAT will not be held liable for damage
to the machine deriving from non-compliance
with this rule.
Press the STOP button to stop the machine.
Operating temperature should be between 15° and 35°C.
Humidity should be between 30 and 60%.
FRIGOMAT s.r.l. will not be held liable for personal harm and/or damage to objects
deriving from incorrect installation and/or by failure to comply with work accident-
prevention standards. Never intervene on the machine with your hands, neither during
normal operating cycles nor during cleaning and maintenance, without first having stopped
the machine by pressing the ON/OFF button and having turned off the master switch.
Never clean the appliance using a high-pressure water jet. Never shut the water cut-off
cock while the machine is running. Be careful never to damage the power cable. If so,
have it replaced.
Machines with water cooling which are left in places at a temperature below or close to
0°C, must first have all the water drained from the condenser.