5 | Parameters overview
24 B0640421_en | Operating instructions Control Panel RBG 3200
5.6 Difference regulator
5.6.1 Difference regulator - Status
Heat source temperature
Display of the current heat source temperature of the differential controller (e.g. tiled stove with
water pocket, …).
Heat sink sensor
Display of the current temperature of the heat sink for the differential controller (e.g. layered
tank, …).
Pump speed
Specifies the current speed of the differential controller pump.
5.7 Circulation pump
5.7.1 Circulation pump - Status
Return temperature in circulation line
Display of the current temperature at the return feed sensor of the circulation line.
NOTICE!If the parameter “Return sensor present” is set to “NO”, 0°C is permanently
displayed.
Flow switch on the domestic hot water line
0: Flow switch detects no flow rate.
1: Flow switch detects flow rate.
Speed of the circulation pump
Specifies the current speed of the circulation pump.