Technical data
Special voltages
NOTE!
Danger due to insufficiently dimensioned electrical installations.
Incorrectly dimensioned mains plugs, mains supply leads and fuse protection can lead to
serious damage to (or loss of) property.
▶
If the power source is designed to run on a special voltage, the Technical Data
shown on the rating plate apply. The mains plug and mains supply lead, and their
fuse protection, must be dimensioned accordingly.
DPS 2500
Mains voltage 3 x 400 V
Mains voltage tolerance + / -15 %
Netzfrequenz 50 / 60 Hz
Mains fuse protection 35 A (slow blow)
Primary continuous power (100 % d.c.*)
24,3 kVA
Cos phi 0,99
Operating current range (continuous) 20 - 250 A
Operating current at 10 min / 40°C (104°F)
60 % d.c.* / 250 A
100% d.c.*/ 200 A
Open-circuit voltage 140 V
Operating voltage up to 70 V
Degree of protection IP 23
Type of cooling AF
Insulation class F
Dimensions (with interface) L x W x H 750 x 310 x 480 mm
29.5 x 12.2 x 18.9 in.
Weight 35.6 kg
78.5 lbs.
Marks of confirmity CE, CSA
Idle state power consumption at 400 V 36.1 W
Power source efficiency at 250 A / 70 V 89%
* d.c. = duty cycle
Overview with
critical raw mate-
rials, year of pro-
duction of the
device
Overview with critical raw materials:
An overview of which critical raw materials are contained in this device can be found at
the following Internet address.
www.fronius.com/en/about-fronius/sustainability.
49
EN