EasyManua.ls Logo

Fronius DPS 2500 - Troubleshooting and Error Code Reference; Troubleshooting Safety and Initial Error Codes

Fronius DPS 2500
52 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Safety The digital power sources are equipped with an intelligent safety system - which has
made it possible to dispense with melting-type fuses entirely. After a possible malfunction
or error has been remedied, the power source can be put back into normal operation
again without any fuses having to be changed.
WARNING!
Danger of electrical shock.
An electric shock can be fatal. Before opening the device
Turn the mains switch to the "O" position
Unplug the device from the mains
Ensure the device cannot be switched back on
Using a suitable measuring instrument, check to make sure that electrically charged
components (e.g. capacitors) have been discharged
WARNING!
Danger from inadequate ground conductor connection.
An inadequate ground conductor connection can cause serious injury or damage.
The housing screws provide a suitable ground conductor connection for earthing the
housing. The housing screws must NOT be replaced by any other screws that do
not provide a reliable ground conductor connection.
If any error message that is not described here appears on the displays, then the fault is
one that can only be put right by a service technician. Make a note of the error message
shown in the display, and of the serial number and configuration of the power source,
and get in touch with our after-sales service, giving them a detailed description of the
error.
Displayed service
codes
Code n°: 0
No error - power source is ready
-
Cause:
Remedy:
Code n°: 2 to 4
Over-temperature in the secondary circuit of the power source
Allow the power source to cool down
Cause:
Remedy:
Code n°: 5 to 10
Over-temperature in the primary circuit of the power source
Allow the power source to cool down
Cause:
Remedy:
Code n°: 11
Error in temperature sensor n° 1
Contact After-Sales Service
Cause:
Remedy:
Code n°: 12
Error in temperature sensor n° 2
Contact After-Sales Service
Cause:
Remedy:
44