- The IP 45 protection system means that the FRONIUS IG can be ex-
posed to moisture. However we recommend if possible that direct mois-
ture is avoided.
- In spite of the IP 45 protection system the FRONIUS IG Outdoors
should if possible not be exposed to the effects of the sun as there is no
display film worldwide that is resistant to UV-Rays over a period of time.
However to achieve a long life the FRONIUS IG Outdoors has an exteri-
or casing and a display with a cover slide.
- The protection of the display unit provided by the cover slide also incre-
ases the life of the film. (The ideal situation is choosing a partially pro-
tected fitting position for the FRONIUS IG Outdoors with exterior casing
e.g. in the area of the solar module, or under a projecting roof).
- FRONIUS IG can be installed vertically as well as horizontally - accor-
ding to chapter „Fixing the wall mounting for FRONIUS IG Outdoors“.
- For use in environments with heavy dust development: If necessary
remove the fan plates and clean the integrated fly screen
Do not install the inverter:
- where it can be exposed to ammonia, corrosive gasses, acids or salts
(e.g., fertilizer storage areas, vent openings of livestock stables, chemi-
cal plants, tanneries)
Choosing the
location -
outdoor hou-
sing
Choosing the
location -
indoor hou-
sing
(continued)
- storage or processing areas for fruit, vegetables or winegrowing pro-
ducts
- areas used in the preparation of grain, green fodder or animal feeds
- greenhouses