63
ENEN
- Equipping a FRONIUS IG with a datalogger card
(Illustration: FRONIUS IG 2)
- Equipping all FRONIUS IGs with a COM Card
The data recorder has two RS-232 interfaces for the connection with
personal computer and modem.
COM Card
(5)
OUT
IN
Data recorder
PC
(5)
(6)(6)(6)
COM Card
COM Card
(5) Blind plug
(6) Data cable
Sensor Box in
external Housing
IN OUT
IN OUT
PC
IN
OUT
ENS
ENS
ENS
RS-232
Note! Basically the order of sequence for placing the cards does
not matter.
Important however is:
- One FRONIUS IG can have only one COM card
- One network can contain only one data recorder.
More information on the various system upgrade possbilities you will find in
the respective service manuals or in the internet under www.fronius.com.