EasyManua.ls Logo

Fronius TransPocket 2500 - Troubleshooting Specific Indicator Faults; Indicator Lights for Ground Current, Short Circuit, and More

Fronius TransPocket 2500
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ground current (earth current watchdog option only)
Indicators shown on the right light up, VRD indicator flashes red
Cause: Current flowing via device earth
Remedy: Check ground earth connection to workpiece, switch
machine off and on again; if error keeps recurring, have
machine serviced
Short circuit after switching on the machine
Indicators shown on the right light up, VRD indicator flashes red
Cause: Short circuit between electrode holder and earthing clamp
Remedy: Rectify short circuit, switch machine off and on again; if
error keeps recurring, have machine serviced
Current limit
Indicators shown on the right light up, VRD indicator flashes red
Cause: Internal error
Remedy: Switch machine off and on again; if fault keeps recurring,
have device serviced
ILZ
Indicators shown on the right light up, VRD indicator flashes red
Cause: Internal error
Remedy: Switch machine off and on again; if fault keeps recurring,
have device serviced
Asymmetry (during operation)
Indicators shown on the right light up, VRD indicator flashes red
Cause: Internal error
Remedy: Switch machine off and on again; if fault keeps recurring,
have device serviced
Asymmetry (when switching on)
Indicators shown on the right light up, VRD indicator flashes red
Cause: Internal error
Remedy: Switch machine off and on again; if fault keeps recurring,
have device serviced
Primary current
Indicators shown on the right light up, VRD indicator flashes red
Cause: Internal error
Remedy: Switch machine off and on again; if fault keeps recurring,
have device serviced
37
EN

Table of Contents

Related product manuals