I-S
I (current) - Starting current
 
 
 
 
Unit % (of starting current)  
Setting range 0 - 200
Factory setting 135  
SL
Slope
 
 
 
 
Unit s  
Setting range 0.1 - 9.9  
Factory setting 1.0  
I-E
I (current) - End - Final current
 
 
 
 
Unit % (of starting current)  
Setting range 0 - 200
Factory setting 50  
FAC
Reset power source to factory setting
Press and hold down the Store button for 2 s to restore the factory settings
when "PrG" appears on the digital display, the power source has been reset
 
NOTE!
When the power source is reset, all the customised settings in the Setup menu are
lost.
When the power source is reset, jobs are not deleted but are retained in the memory.
The functions in the second level of the Setup menu (2nd) are also not deleted. Excep-
tion: Ignition time-out welding parameter (ito).
2nd
Second level of the Setup menu (see “Setup menu - level 2”)
t-S
time - Starting current - Starting current duration
Unit s  
Setting range OFF or 0.1 - 9.9
Factory setting OFF  
t-E
time - End current - Final current duration
Unit s  
Setting range OFF or 0.1 - 9.9
Factory setting OFF  