EasyManua.ls Logo

Fronius VR 4000 - Side of Wire-Feed Unit

Fronius VR 4000
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Side of wire-feed
unit
VR 4000 - side view
(1) Wirespool holder with brake
for attaching standardised wirespools up to max.16 kg (35.27 lbs.) and with a max-
imum diameter of 300 mm (11.81 in.)
(2) 4-roller drive
(3) "Wire threading/gas test" button
1)
To feed the wire electrode into the torch hosepack with no accompanying flow of
gas or current. While the button is held down, the wire-feed unit runs at feeder inch-
ing speed.
Push button upwards
to set the required gas flow rate at the pressure regulator. As long as the button is
pressed up, gas flows out.
The "wire threading/gas test" button (5) can also be installed as a separate option
on the VR 4000.
(4) Mode selector switch
1)
for selecting the following modes:
2-step mode
4-step mode
Special 4-step mode (aluminium welding start-up)
Spot welding
(5) Process selector switch
1)
for selecting the following processes
MIG/MAG Pulse-Synergic
MIG/MAG Standard-Synergic
MIG/MAG standard manual welding
Job welding
TIG welding with touch-down ignition
MMA welding
1)
"Mode selector switch" option
(2)(1)
(3)
(5)
(4)

Table of Contents

Other manuals for Fronius VR 4000

Related product manuals