At least one phase of the power supply is missing
The phase(s) of the supply line to the Wattpilot has/have
failed. Check the phase(s) of the supply line. For more
information, see Status Codes on page 67.
-
The LEDs light up blue, the LEDs at the top flash
red.
Temperature too high
The temperature of the Wattpilot is too high. The char-
ging current is reduced. For more information, see
Status Codes on page 67.
-
The LEDs light up yellow, the LEDs at the top flash
red.
Unlocking or locking error
Unlocking or locking has failed. The unlocking or locking
attempt is repeated at 5-second intervals. For more in-
formation, see Status Codes on page 67.
-
The LEDs light up red at the top and yellow at the
bottom for 1 second.
Charge controller error
The charge controller is not working properly. For more
information, see Status Codes on page 67.
-
The LEDs light up red at the top and yellow at the
bottom for 1 second.
Update
The Wattpilot firmware is being updated. The update can
take several minutes. Do not unplug the charging station.
-
All LEDs flash pink, the progress of the update is in-
dicated by yellow LEDs.
Update successful
-
The LEDs light up alternately pink and green.
Update failed
-
The LEDs light up alternately pink and red.