Do you have a question about the Fronius Selectiva and is the answer not in the manual?
Efficiency | > 90% |
---|---|
Battery Types | Lead-acid, GEL, AGM |
Protection Class | IP20 |
Protection Features | Overvoltage, Short-circuit, Reverse polarity |
Output Voltage | 12/24 V DC |
Device manufactured to state of art, but misuse can cause injury or damage.
Electrical hazards from grid/charging current and electromagnetic fields. Ensure proper earthing.
Batteries contain acid; charging produces explosive gases. Use in ventilated rooms.
Keep people, especially children, away. Inform about dangers and provide protection.
Operate with ground conductor, check rating plate, do not commission damaged device, inspect leads.
Work must be by authorized personnel using original parts. Modifications require manufacturer approval.
Recommend safety inspection every 12 months by qualified electrician.
Active Inverter Technology for intelligent charging, adapting to battery state for extended life and efficiency.
Danger from incorrect operation. Read all instructions before use.
For charging specific battery types (lead acid, NiCd, Li-ion). Other uses are not intended.
Serious injury/damage from leaking batteries. Only charge listed types.
Serious injury/damage from escaping gases, ignition, or explosion. Connect suitable batteries.
Features include reverse polarity, short-circuit, overcharging, and overtemperature protection.
Connect leads, select characteristic type, and connect to battery poles.
Warnings about electric shock and inadequate ground conductor connection before opening device.