EasyManua.ls Logo

Fronius Selectiva - Technical data; Selectiva 1 kW

Fronius Selectiva
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Selectiva 1 kW
Mains voltage (+/- 15%) ~230 V
Mains frequency 50/60 Hz
Mains fuse 16 A
Battery backfeed current < 1 mA
Standby consumption max. 1.7 W
Safety class I
Max. permitted grid impedance Z
max
on
PCC
None
EMC emission class A
Dimensions L x W x H 247 x 162 x 88 mm
(9.72 x 6.38 x 3.46 in)
Weight (without cables)
1020 | 1030 | 2010 | 2015
2020 | 2032 | 2040
2.1 kg (4.63 lb.)
2.2 kg (4.85 lb.)
Cooling
1020 | 1030 | 2010 | 2015
2020 | 2032 | 2040
Convection
Convection and fan
Operating temperature
(>30 °C / >86 °F derating)
-20 °C to +40 °C
(-4 °F to 104 °F)
Storage temperature -40 °C to +85 °C
(-40 °F to 185 °F)
Relative humidity maximum 85 %
Maximum altitude above sea level 2000 m (6561 ft.)
Protection class IP 40
Mark of conformity According to rating plate
Housing A1
Product standard IEC 60068-2-27 (shock)
IEC 60068-2-29 (bump)
IEC 60068-2-64 (vibration)
EN 60335-1
EN 60335-2-29
EN 61000-3-2
EN 61000-6-2 (EN 61000-4-2,
EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6,
EN 61000-4-11)
EN 61000-6-4 (Class A)
Device-specific data
Device
Grid cur-
rent max.
Effective
power
max.
Nominal
output
voltage
Output
voltage
range
Output
current
1020 2.3 A 315 W 12 V DC /
6 cells
2 V to
16.8 V DC
20 A at
14.4 V DC
25

Related product manuals