Personal protec-
tion and protec-
tion of others
Keep persons, especially children, away from the device and working area during
operation. However, if persons are in the vicinity:
-
Inform them of any dangers (hazardous acids and gases, risk due to grid and
charging current, etc.),
-
Provide suitable protective equipment.
Before leaving the working area, ensure that no personal injury or property dam-
age can occur in your absence.
Safety measures
in normal opera-
tion
Operate devices with ground conductors only on a grid with a ground conductor
and a socket with a ground conductor contact. Operating the device on a grid
without a ground conductor or on a socket without a ground conductor contact is
considered gross negligence. The manufacturer accepts no liability for any dam-
age resulting from improper use.
Only operate the device in accordance with the protection class shown on the
rating plate.
Never commission the device if it is damaged.
Have the grid and device supply lead regularly inspected by an electrician to en-
sure that the ground conductor is functioning properly.
Safety devices that are not fully functional and components with defects must
be repaired by an authorized specialist before the device is turned on.
Never bypass or disable protection devices.
A freely accessible mains plug is required after installation.
EMC device clas-
sifications
Devices with emission class A:
-
Are only designed for use in an industrial setting.
-
Can cause conducted and emitted interference in other areas.
Devices with emission class B:
-
Satisfy the emissions criteria for residential and industrial areas. This also
applies to residential areas in which power is supplied from the public low-
voltage grid.
EMC device classification according to the rating plate or the technical data.
EMC measures In certain cases, even though a device complies with the standard limit values for
emissions, it may affect the application area for which it was designed (e.g. when
there is sensitive equipment at the same location, or if the site where the device
is installed is close to either radio or television receivers).
If this is the case, then the operating company is obliged to take appropriate ac-
tion to rectify the situation.
Data security With regard to data security, the user is responsible for:
-
backing up any changes made to the factory settings
-
saving and retaining personal settings
6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Selectiva and is the answer not in the manual?

Fronius Selectiva Specifications

General IconGeneral
Efficiency> 90%
Battery TypesLead-acid, GEL, AGM
Protection ClassIP20
Protection FeaturesOvervoltage, Short-circuit, Reverse polarity
Output Voltage12/24 V DC