EasyManua.ls Logo

Fronius Selectiva 3.0 - User Manual

Fronius Selectiva 3.0
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Op erating
Instructions
Selectiva 3.0
8 - 16 kW
42,0426,0362,EN 008-12052022
EN
Operating Instructions

Table of Contents

Other manuals for Fronius Selectiva 3.0

Question and Answer IconNeed help?

Do you have a question about the Fronius Selectiva 3.0 and is the answer not in the manual?

Fronius Selectiva 3.0 Specifications

General IconGeneral
BrandFronius
ModelSelectiva 3.0
CategoryBattery Charger
LanguageEnglish

Summary

Power Categories and Model Identification

General Power Category Information

Explains that kW information relates to housing design, not actual output.

8 kW 400 V Model Numbers

Lists specific model numbers for the 8 kW 400 V power category.

16 kW 220 V Model Numbers

Lists specific model numbers for the 16 kW 220 V power category.

16 kW 400 V Model Numbers

Lists specific model numbers for the 16 kW 400 V power category.

Safety Rules and Precautions

General Safety Guidelines and Operator Qualifications

Outlines general safety standards, potential dangers, and operator qualifications.

Environmental and Mains Connection Safety

Covers environmental operation and safety aspects of mains connection.

Electrical and Chemical Hazards

Dangers from Mains Current and Electromagnetic Fields

Details dangers from mains/charging current and electromagnetic fields.

Battery Acid, Gases, and Ventilation Hazards

Warns about battery acid, explosive gases, and the need for ventilation.

General Battery Handling and Storage Precautions

Provides guidance on battery protection, storage, and inspection.

Operational Safety and EMC Considerations

Personal Safety and Work Area Precautions

Advises keeping people away and providing protective equipment.

Standard Operation and Device Integrity Checks

Covers grounding, operating conditions, and maintenance checks.

EMC Device Classification and Measures

Explains emission classes and measures to rectify interference.

Data Protection and Device Markings

States user responsibility for settings and explains CE/EAC markings.

Maintenance, Repair, and Inspection Procedures

Pre-Operation Checks and Cleaning Procedures

Advises checking mains plug/cable and cleaning the device.

Authorized Maintenance and Safety Inspections

States authorized personnel, original parts, and annual safety inspections.

Operator Obligations and Device Disposal

Lists operator qualifications and proper disposal instructions.

Understanding Safety Notices and Device Functionality

Explanation of Safety Notice Symbols

Defines danger, warning, caution, and note symbols used in the manual.

Device Concept and Intelligent Charging Technology

Describes the charger's intelligent charging technology and robust housing.

Proper Use and Intended Purpose

Defines the intended purpose of the charger and proper usage guidelines.

Mains Connection Safety Requirements

Battery Compatibility and Electrical Hazards

Warns about incompatible batteries, electrical current dangers, and RCD type.

Operational and Power Supply Safety

Warns of injury/damage from incorrect operation and faulty power supply.

Charging Lead and Cable Installation Safety

Hazards of Trailing Charging Leads and Plug Disconnection

Warns of tripping hazards and fire/explosion risk from plug disconnection.

Overheating Danger from Incorrect Cable Laying

Warns of component damage due to incorrect cable laying and overheating.

Device Warning Labels and Electrical Safety Measures

Safety Symbols and Housing Access Restrictions

States safety symbols must remain and housing access is restricted.

Ignition Sources, Explosion Risk, and Acid Hazards

Advises keeping ignition sources away from batteries due to explosion risk and acid hazards.

RCD Requirements and Product Disposal

Specifies RCD type and instructs on product disposal.

Internal Device Warnings and Setup Regulations

Internal Electrical Shock Hazards and Safety Measures

Warns of internal electrical shock hazards and safety measures.

Securing Devices and IP20 Rating Explanation

Warns of injury/damage from falling devices and explains IP20 rating.

Device Operation and Cooling Requirements

Horizontal Operation and Airflow Management

States horizontal operation requirement and managing airflow for cooling.

Air Inlet;Outlet Clearance and Quality

Specifies clearance for air inlets/outlets and air quality requirements.

Warning Against Covering Air Inlets;Outlets

Warns of damage due to partially or fully covered air inlets and outlets.

Wall Bracket Installation Safety Guidelines

Hazards of Incorrect Installation and Falling Devices

Warns of injury/damage from incorrect installation and falling devices.

Securing Devices Against Falling or Toppling

Warns of injury/damage from falling/toppling devices and securing connections.

Device Dimensions: 8 kW and 16 kW Models

Dimensions and Mounting Points for 8 kW Models

Provides detailed dimensions and mounting hole layout for 8 kW models.

Dimensions and Mounting Points for 16 kW Models

Provides detailed dimensions and mounting hole layout for 16 kW models.

Mounting Bracket Specifications

Drilling Template for Wall Bracket Installation

Details the drilling template for the wall bracket.

Wall Bracket Weight Information

Lists the weight of the wall bracket for 8 kW and 16 kW models.

Controls and Connections Overview

USB Port and Connection Area Details

Describes USB port, connection area, and safety notices for options.

Charging Lead and External Option Connections

Identifies charging lead and external option connections like air pump.

Device Ports and Option Plug Details

Mains Cable, LED Strip, and Control Panel Identification

Identifies mains cable, optional LED strip, and the control panel.

18-Pin Option Plug Pinout and Connections

Details connections for the 18-pin option plug on the PC board.

Option Plug Pin Assignments

Pin Functions for External Indicators and Power

Lists pin assignments for external LEDs and power supply.

Pin Functions for Control and Error Signals

Lists pin assignments for remote control and error indicators.

Pin Functions for Battery Status and Charging

Lists pin assignments for battery status and charging functions.

Control Panel Interface and Indicators

Display Screen and Menu Navigation Keys

Explains the display and navigation keys like Menu, Up/Down.

Value Adjustment and Pause;Start Key Functions

Describes value adjustment keys and the Pause/Start key.

Status Indicators: Battery Cooled and Fault

Explains the blue (Battery cooled) and red (Fault) indicators.

Control Panel Status Indicators Explained

Warning Indicator (Flashing Red) and Charge Indicator (Yellow)

Explains the flashing red warning indicator and yellow charge indicator.

Battery Charged Indicator (Green)

Explains the green indicator for charging completion.

Initial Device Setup and Configuration

Language and Basic Settings Upon First Connection

Guides through selecting language and other basic settings upon first connection.

Time Zone, Daylight Saving, and Date;Time Adjustment

Details setting time zone, daylight saving, and adjusting date/time.

Charging Cable and Battery Configuration

Setting Charging Cable Length and Cross-Section

Guides on setting charging lead length and cross-section and their impact.

Confirming Battery Type and Default Parameters

Instructs to confirm battery type, characteristic, and default parameters.

Initiating the Charging Process

Warning: Incorrect Battery Type or Settings

Warns about injury/damage from incorrect battery type or charge settings.

Charging Plug Cleanliness and Connection

Advises on plug cleanliness and connecting the plug to start charging.

Displayed Charging Parameters Overview

Details parameters shown on the display during standard mode.

Battery Charge Status and Interruption

Understanding Battery Symbol and Minute Counter Displays

Explains the battery symbol and minute counter for charge status.

Toggling Between Charge Displays

Guides on switching between minute counter and standard display.

Indicators for Fully Charged Battery

Describes indicators when the battery is fully charged.

Interrupting Charging with Pause;Start Key

Explains how to interrupt charging using the "Pause/Start" key.

Resuming and Stopping Charging Safely

Resuming Charging and Danger of Oxyhydrogen Ignition

Details resuming charging and warns about oxyhydrogen ignition risk.

Hazards of Plug Disconnection and Battery Damage

Warns of injury/damage from plug disconnection and battery damage.

Indicators for Fully Charged and Cooled Battery

Describes the green and blue indicators for a fully charged and cooled battery.

Procedure for Stopping the Charging Process

Steps to Stop Charging Process

Outlines the steps to stop the charging process.

Overview of Display Modes

Standard, Statistics, and History Mode Descriptions

Describes Standard, Statistics, and History modes for viewing data.

Configuration and USB Mode Functions

Explains Configuration and USB modes for settings and data management.

Display Mode Availability During Charging Pauses

Notes limited menu selection during charging pauses.

Navigating Display Menus

Switching to Menu Selection and Selecting Modes

Guides on switching to menu selection and selecting desired modes.

Statistics Mode: Operating Statuses and Charge Summary

Shows operating statuses and charge summary data in statistics mode.

History Mode Data and Symbols

Viewing Stored Charging Process Parameters

Shows display windows for stored charging processes and their parameters.

Navigating History Data and Understanding Symbols

Guides history data navigation and explains display symbols.

Configuration Mode: Charging Settings

Battery Type, Characteristic, and Voltage Settings

Details settings for battery type, characteristic, capacity, and voltage.

Warning: Battery Damage from Incorrect Cell Settings

Warns of battery damage if cell number is set incorrectly.

Additional Charging Characteristic Options

Allows for individual adaptation options for the charging characteristic.

Overview of Additional Functions

Lists additional functions like Blue LED, External start/stop, Refill indicator.

General Options and Menu Access Procedures

General Settings Menu Items and USB Logging

Lists settings like Language, Contrast, Time zone, USB logging.

Reset Settings Procedure and Configuration Menu Access

Explains reset settings confirmation and configuration menu access via code.

Navigating Configuration Submenus

Selecting Main Menu Items and Submenus

Guides on selecting main menu items and navigating submenus.

Confirming Entries and Example Charging Settings

Guides on confirming entries and demonstrates setting charging parameters.

Charging Settings Configuration Details

Setting Charging Time, Cells, and Confirming Changes

Guides on setting charging time, cells, and confirming changed settings.

Example: Changing Charging Characteristic

Shows an example of changing the charging characteristic.

Settings Menu: Electrolyte Circulation

Air Pump Electrolyte Circulation Feature

Describes the "Air Pump" electrolyte circulation feature.

Electrolyte Circulation Operational Settings

Lists settings for electrolyte circulation: Off, Continuous, Program, Automatic, User.

Electrolyte Circulation Programs and Temperature Control

Circulation Program Timings and Over-temperature Settings

Details circulation program timings and over-temperature settings.

Temperature-Controlled Charging and Sensor Requirements

Explains temperature-controlled charging settings and sensor requirements.

Equalising Charge Functionality

Equalising Charge Options: OFF, Delay, and Weekday

Covers options for no equalising charge, delay, and weekday scheduling.

Manual Equalising Charge Start and Indication

Explains manual start and indication of equalising charge.

Delay and Calendar Function Settings

Delay Settings for Charging Start and End

Defines delay times for charge start and end.

Calendar Function Activation and Charging Settings

Guides on activating the calendar function and its charging settings.

Calendar Function: Day and Week Settings

Day Setting Profiles for Charging Start Times

Allows defining up to five charging start time profiles.

Time Windows and Week Setting Profiles

Explains time windows and defining three week settings.

Note on Ongoing Charging Operations During Time Window Changes

Clarifies how time windows affect ongoing charging.

Calendar Year Settings and Special Charges

Year Setting for Calendar Periods

Allows defining multiple periods with single week settings.

Special Charges Functionality and Repeat Settings

Allows performing alternative charging types and setting repeat count.

Disabling Start Button and Special Charge Parameters

Prevents unauthorized intervention and lists special charge parameters.

Special Functions: Opportunity Charge and DC Connection

Opportunity Charge for Extended Battery Usage

Allows recharging at times when not needed to extend battery usage.

Starting Opportunity Charging and DC Connection Check

Guides on starting opportunity charging and checking DC connection.

Additional Functions Menu Navigation

Selecting Additional Functions and Blue LED Settings

Guides on selecting additional functions and setting the Blue LED.

External Start;Stop Function Settings

Details settings for external start/stop functionality.

External Controls and Relay Outputs

Simulating Pause;Start Button and Contact Detection

Explains external button simulation and contact detection settings.

Refill Indicator and Relay Output Functionalities

Details refill indicator and lists relay output functionalities.

Aquamatic Control for Battery Water Topping

Describes Aquamatic control for automatic battery water topping.

Relay Output Options Explained

Charging Status Outputs and Error;Warning Signals

Covers options for charging status, errors, and warnings.

Signal Lamp, Immobiliser, and Refill Indicator Functions

Details Signal Lamp, Immobiliser, and Refill Indicator functions.

External Air Pump and External Lamp Settings

Details settings for External Air Pump and External Lamp.

Remote Control and General Options Configuration

Remote Control System Contrast Adjustment

Allows adjustment of the contrast for the remote control system.

General Settings: Language, Display, and Time

Lists general settings like Language, Display, Time, and Charging cable.

AC Current, Temperature, and USB Logging Settings

AC Current Consumption and Temperature Unit Settings

Allows adapting current consumption and setting temperature units.

USB Logging Time Interval and Reset Settings

Sets USB logging interval and explains reset settings.

USB Mode Operations and Firmware Updates

USB Flash Drive Requirements and Navigation

Lists USB drive requirements and guides navigation in USB mode.

Safely Removing USB Drive and Updating Firmware

Advises safe USB removal and explains firmware update procedure.

Data Management via USB and Status Codes

Saving Data to USB and Download Options

Details saving logged data, events, and download options.

Loading Configurations and Dealer Text from USB

Explains loading configurations and dealer text from USB.

Status Code (31) for Battery and Charging Issues

Indicates Statecode 31 for battery and charging problems.

Troubleshooting: Battery Faults and External Factors

Battery Fault Causes, Resolution, and External Factor Codes

Lists battery fault causes, resolution steps, and external factor codes.

Specific Battery Fault Status Codes

Lists codes for battery undervoltage, overvoltage, temperature, and cell faults.

Troubleshooting: CAN, Gateway, and Charging Errors

CAN Fault Codes and Gateway Connection Errors

Lists codes for CAN communication and gateway connection errors.

Charging Error Codes and Primary Circuit Faults

Lists codes for charging errors and primary circuit faults.

Troubleshooting: Primary and Secondary Circuit Faults

Primary Circuit Faults: Voltage, Configuration, and Phase Shifter

Lists codes for intermediate circuit, voltage, configuration, and phase shifter faults.

Secondary Circuit Faults: Sensors, Fuses, and Microcontrollers

Lists codes for secondary sensors, fuses, voltage, current, and microcontroller faults.

Troubleshooting: Controller Faults

Controller Faults: Memory, Initialization, and Update Failures

Lists codes for memory, initialization, and update failures.

Controller Faults: Settings, Communication, and Software Issues

Lists codes for settings load/save, communication, and software issues.

Controller Faults: InterLock and Compatibility Issues

Lists codes for InterLock communication and device compatibility.

Options: Safety Precautions for Components

Electrical Shock Hazards and Housing Access Safety

Warns of electric shock hazard and safety measures for opening the housing.

Improper Work Hazards and Device Falling Dangers

Warns of injury/damage from improper work and falling devices.

Electrolyte Circulation: Air Pump and Back Pressure Note

Warns of damage to the air pump from electrolyte ingress or no back pressure.

Electrolyte Circulation System Details

Mains Voltage Tolerance and Air Pump Functionality

Warns about voltage tolerance and explains the air pump for electrolyte circulation.

Fault Detection and Air Filter Cleaning

Details fault detection and instructs on cleaning the air filter.

External Start;Stop and Charging Lights

External Start;Stop Functionality and Spark Prevention

Explains how the option prevents sparking during plug disconnection.

Connecting External Lamps for Charge Status Indication

Details connecting external lamps for charge status indication.

Charging Lights, Temperature Control, and Relay Board Safety

Charging Lights Pinout, Functions, and RGB Setting

Shows pinout, functions, and RGB setting for charging lights.

Temperature-Controlled Charging and Relay Board Warnings

Explains temperature control and warns about relay board safety.

Relay Board Outputs and Aquamatic Control

Relay Board Outputs for Status Evaluation and Options

Enables external status evaluation and lists relay-connected options.

Aquamatic Control: Standard and User Settings

Describes Aquamatic control for automatic battery water topping.

Relay Output Options: Charging and Error Signals

Charging Status Outputs and Error;Warning Signals

Covers options for charging status, errors, and warnings.

Signal Lamp, Immobiliser, and Refill Indicator Functions

Details Signal Lamp, Immobiliser, and Refill Indicator functions.

Additional Options: Brackets, LEDs, and Air Filters

Battery Cooling, Air Pump, and Bracket Installation

Covers battery cooling relay, air pump activation, and bracket installation.

LED Strip, IP Protection, Air Filter, and Mobile Kit

Details LED strip, IP protection, air filter, and mobile kit.

Remote Control System Functionality

Allows full control from up to 30 m distance with an aluminum housing.

Technical Data: Selectiva 8 kW 400 V

Mains, EMC, Protection, and Temperature Specifications

Specifies mains voltage, EMC, protection class, and temperature ranges.

Dimensions, Weight, and Contamination Degree

Provides device dimensions, weight, and contamination degree.

Device-Specific Data: 8 kW Models

AC Current, Power, Voltage, and Charging Current for 8 kW Devices

Lists AC current, power, voltage, and charging current for 8 kW devices.

Technical Data: Selectiva 16 kW 220 V

Mains, EMC, Protection, and Temperature Specifications

Specifies mains voltage, EMC, protection class, and temperature ranges.

Dimensions, Weight, and Contamination Degree

Provides device dimensions, weight, and contamination degree.

Device-Specific Data: 16 kW 220 V Models

AC Current, Power, Voltage, and Charging Current for 16 kW 220 V

Lists AC current, power, voltage, and charging current for 16 kW 220V models.

Technical Data: Selectiva 16 kW 400 V

Mains, EMC, Protection, and Temperature Specifications

Specifies mains voltage, EMC, protection class, and temperature ranges.

Dimensions, Weight, and Contamination Degree

Provides device dimensions, weight, and contamination degree.

Device-Specific Data: 16 kW 400 V Models

AC Current, Power, Voltage, and Charging Current for 16 kW 400 V

Lists AC current, power, voltage, and charging current for 16 kW 400V models.

Related product manuals