Program ON 1 OFF 1 Repeat ON 2 OFF 2
1 30 min 25 min 1 x 5 min 25 min
2 3 min 10 min 4 x 3 min 20 min
3 3 min 12 min 1 x 3 min 12 min
4 5 min 10 min 3 x 5 min 20 min
5 2,5 min 7,5 min 1 x 2,5 min 7,5 min
In each of these programs, the solenoid valve opens for a time "ON 1" and closes
for a time "OFF 1". This process is repeated for the number of times specified
under "Repeat". After this number of repetitions has been completed, the pro-
cess continues with the "ON 2" and "OFF 2" times until charging is completed.
Temperature-
controlled char-
ging
Temperature-controlled charging:
The following settings are available for temperature-controlled charging:
automatic/OFF/required
-
automatic ... Temperature-dependent adjustment of the charging character-
istic.
-
OFF ... The measured battery temperature is not taken into account.
-
required ...
Charging only starts if the temperature sensor is connected.
Error overtemperature ON/OFF
-
ON ... Error message in the event of battery overtemperature.
Charging process stops and can only be continued once the battery has
cooled down and been reconnected.
-
OFF ... No error message in the event of battery overtemperature.
Warning overtemperature ON/OFF
-
ON ... Warning in the event of battery overtemperature.
-
OFF ... No warning in the event of battery overtemperature.
An external temperature sensor is required for certain characteristics. If this
type of characteristic is selected in configuration mode, a note is shown indicat-
ing that an external temperature sensor is required.
The following characteristics require an external temperature sensor:
-
28 - FCC IUI - CSM WET
-
30 - FCC IUI - WET
39