Warning notices
inside the device
WARNING!
Danger from electric current.
This can result in serious injury or death.
▶
The housing must never be opened by anyone other than a service technician
trained by the manufacturer.
▶
Before starting work, switch off all the devices and components involved and
disconnect them from the grid.
▶
Secure all the devices and components involved to prevent unintentional re-
starting.
▶
After opening the device, use a suitable measuring instrument to check that
electrically charged components (such as capacitors) have been discharged.
▶
Use an easily legible and understandable warning sign to ensure that the
device is not reconnected to the mains supply before all the work has been
completed.
WARNING
Hazardous Voltage
Kondensator Entladezeit < 3 min.
Capacitor discharge time < 3 min.
Décharge de condensateur < 3 min.
Condensador tiempo de descarga < 3 min.
Condensatore tempo di scaricamento < 3 min.
Setup regula-
tions
WARNING!
Danger from machines falling or toppling over.
This can result in serious injury and damage to property.
▶
Make sure that all system components are securely in position when setting
them up.
▶
If using a floor bracket or wall bracket, always make sure that all the fasten-
ings are secure.
▶
Devices weighing more than 25 kg (55.12 lb.) must be carried by at least two
people.
▶
If mounting on shelves, the shelf must be capable of supporting the weight
of the device.
The device is tested to "Degree of protection IP20", meaning:
-
Protection against penetration by solid foreign bodies with diameters ex-
ceeding 12.5 mm (0.49 in.).
-
No protection against water.
The device can be set up and operated in dry, closed areas that comply with de-
gree of protection IP20. Exposure to wet conditions should be avoided.
15
EN