Technical data
Selectiva 8 kW
400 V
WARNING!
An electric shock due to a fault current can be fatal.
Nothing other than a type B residual current circuit breaker should ever be used
for connecting the device to the mains.
Mains voltage (-10%/+30%)
1)
Optional:
3~ NPE 400 V / 50/60 Hz
3~ PE 400 V/50/60 Hz
Mains fuse protection
2)
16 A
Minimum mains lead cross section 2.5 mm² (0.003875 in.²)
Duty cycle 100%
EMC device class B
Standby consumption
24 V devices
48 V devices
80 V devices
10 W
10.1 W
10.3 W
Protection class I
Max. permitted mains impedance Z
max
on
PCC
3)
None
Degree of protection
4)
IP 20
Overvoltage category III
Operating temperature
5)
-20°C to +40°C
(-4°F to 104°F)
Storage temperature -25°C to +80°C
(-13°F to 176°F)
Relative humidity max. 85%
Maximum altitude above sea level 2000 m (6561 ft.)
Mark of conformity according to rating plate
Product standard EN 62477-1
Dimensions L x W x H 633 x 180 x 344 mm
(24.92 x 7.09 x 13.54 in.)
Weight (with standard mains and charging
leads)
23 kg (50.71 lb)
Degree of contamination 3
1) The device is approved for operation on neutral-earthed mains networks
with a maximum outer conductor nominal voltage of 400 V. An L-N mains
voltage tolerance of 207 V to 250 V applies for the electrolyte circulation
and relay board options.
63
EN

Table of Contents

Other manuals for Fronius Selectiva 3.0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Selectiva 3.0 and is the answer not in the manual?

Fronius Selectiva 3.0 Specifications

General IconGeneral
BrandFronius
ModelSelectiva 3.0
CategoryBattery Charger
LanguageEnglish

Related product manuals