Selectiva 16 kW
220 V
WARNING!
An electric shock due to a fault current can be fatal.
Nothing other than a type B residual current circuit breaker should ever be used
for connecting the device to the mains.
Mains voltage (-10%/+30%)
1)
Optional:
3~ NPE 220 V/50/60 Hz
3~ PE 220 V/50/60 Hz
Mains fuse protection
2)
32 A
Minimum mains lead cross section
Selectiva 4120
Selectiva 4140/4160
4 mm² (0.0062 in.²)
6 mm² (0.0093 in.²)
Duty cycle 100%
EMC device class B
Standby usage 6.9 W
Protection class I
Max. permitted mains impedance Z
max
on
PCC
3)
According to the "Device-spe-
cific data" table below
Degree of protection
4)
IP 20
Overvoltage category III
Operating temperature
5)
-20°C to +40°C
(-4°F to 104°F)
Storage temperature -25°C to +80°C
(-13°F to 176°F)
Relative humidity max. 85%
Maximum altitude above sea level 3000 m (9842 ft)
Mark of conformity according to rating plate
Product standard EN 62477-1
Dimensions L x W x H 647 x 247 x 392 mm
(25.47 x 9.72 x 15.43 in.)
Weight (with standard mains and charging
leads)
34.84 kg (76.81 lb)
Degree of contamination 3
1) The device is approved for operation on neutral-earthed mains networks
with a maximum outer conductor nominal voltage of 220 V.
2) Nothing other than a type B residual current circuit breaker should ever
be used for connecting the device to the mains. The earth leakage current
is less than 3.5 mA.
3) Interface to a 127/220 V and 50 Hz public grid.
4) For indoor use only, do not expose to rain or snow.
5) A high ambient temperature may result in power degradation (derating).
65