2) Nothing other than a type B residual current circuit breaker should ever
be used for connecting the device to the mains.
If the charger is protected by a 32 A fuse, the thermal stress of the auto-
matic circuit breaker must not exceed 82000 A²s.
The earth leakage current is less than 3.5 mA.
3) Interface to a 230/400 V and 50 Hz public grid.
4) For indoor use only, do not expose to rain or snow.
5) A high ambient temperature may result in power degradation (derating).
Device-specific data
Device Max. AC cur-
rent
Max. AC
power
Nominal
voltage
Max. char-
ging current
2100 8 kW 6.7 A 3860 W 24 V 100 A
2120 8 kW 7.8 A 4590 W 24 V 120 A
2140 8 kW 9.0 A 5350 W 24 V 140 A
2160 8 kW 10.1 A 6090 W 24 V 160 A
2180 8 kW 11.2 A 6860 W 24 V 180 A
2200 8 kW 12.3 A 7610 W 24 V 200 A
2225 8 kW 13.7 A 8560 W 24 V 225 A
4060 8 kW 7.3 A 4610 W 48 V 60 A
4075 8 kW 9.0 A 5710 W 48 V 75 A
4090 8 kW 10.6 A 6820 W 48 V 90 A
4120 8 kW 13.8 A 9050 W 48 V 120 A
4140 8 kW 14.4 A 9340 W 48 V 140 A
4160 8 kW 14.5 A 9390 W 48 V 160 A
4185 8 kW 15.3 A 9950 W 48 V 185 A
8040 8 kW 8.2 A 5000 W 80 V 40 A
8060 8 kW 12.0 A 7440 W 80 V 60 A
8075 8 kW 14.1 A 9110 W 80 V 75 A
8090 8 kW 14.2 A 9210 W 80 V 90 A
8110 8 kW 15.1 A 9740 W 80 V 110 A
64