A note is displayed if a characteristic
that requires an external temperature
sensor is selected.
1
Use the "Pause/Start" key to con-
firm the note.
Equalising
charge
Equalising charge
OFF
-
There is no equalising charge.
Delay
-
If the battery remains connected to the charger for the duration of the
equalising charge delay ("equalize charge delay"), a special type of charging
takes place. This prevents acid stratification.
-
The parameters for the current (ampere/100 ampere hours), voltage (volt/
cell) and duration of the equalising charge may all be changed.
Weekday
-
Specify the weekday on which the equalising charge is to take place.
-
The parameters for the current (ampere/100 ampere hours), voltage (volt/
cell) and duration of the equalising charge may all be changed.
Manual equalising charge (“Manual”)
-
An equalising charge can be started manually by pressing the relevant key on
the display.
-
The equalising charge starts after a set delay time has been observed. The
charge parameters that have been set are followed.
-
The parameters for the current (ampere/100 ampere hours), voltage (volt/
cell) and duration of the equalising charge may all be changed.
-
This function is only available for Pb-Wet characteristics.
If a setting for the equalising charge is enabled, a symbol on the home screen
next to the set ampere hours or charging time shows whether an equalising
charge is being carried out or can be started.
40