Delay "Delay"
"Charge start delay"
-
Delay time (minutes) between the activation time of the charge start and the
actual charge start.
“Charge end delay”
-
Delay time (minutes) between the signaled end of charge (e.g. green indicat-
or) and the actual end of charge.
"At mains failure restart charging"
-
If this option is activated, the charging process is automatically restarted
after a fault in the electrical network as soon as the electrical network is
available again.
"At mains failure"
-
Restart charging
-
Automatic/continue charging
If the "Restart charging" option is activated, the charging process is automatic-
ally restarted after a fault in the electrical network as soon as the electrical net-
work is available again.
If the "Automatic/continue charging" option is activated, the charging process is
automatically continued after a fault in the electrical network as soon as the
electrical network is available again.
Calendar Calendar
The calendar function allows charging to be started automatically according to
the following criteria:
-
Time window in which charging may not be started if a battery is connected.
-
Time window in which charging is to be started using a defined characteristic
1 if a battery is connected.
-
Time window in which charging is to be started using a defined characteristic
2 if a battery is connected.
1
To activate the calendar function,
select the "ON" setting and con-
firm.
"Charging settings" menu item:
-
Type of battery for every charac-
teristic:
e.g. Pb-WET.
-
Curve settings when selecting the
relevant characteristic.
Additional settings can be found under the "Calendar" function:
41
EN