“Charge 50%"
“Charge 80%"
"Charge Finish"
"Main Charge Finished"
-
Signal when main charging phase is finished
“Charge not complete”
-
Signal if the battery is prematurely disconnected from the charger
-
Can be set from 1 to 10 s
"Charge OK"
-
Battery is being charged or is already fully charged
“Cumulative Error”
-
Signal in the event of an error
-
A power failure can be displayed as an error ("ON" setting).
-
If the device is in an error state, a freely defined text can be displayed, which
can contain the contact details of the dealer, for example. Detailed informa-
tion can be found in the "USB mode" section.
Cumulative error + warning
-
In the same way as the "Cumulative error" function, the corresponding relay
picks up as soon as an error or warning is present.
"Signal Lamp"
-
It is possible to connect one or more suitable lamps to the relay board to in-
dicate the state of charge or the operating status of the battery charger.
-
Detailed information can be found in the "Signal lamp" section of the "Op-
tions" chapter.
“Immobiliser”
ON
-
The relay picks up continuously as soon as the battery charger is connected
to the mains.
"Refill Indicator"
-
Indicates that it is necessary to refill the battery with distilled water.
-
Detailed information can be found in the "Additional functions" section of
the "Display" chapter.
"Battery Cold"
"External Air Pump"
-
The settings are made as explained in section "-> Settings" for electrolyte cir-
culation ("Air Pump").
Detailed information on the relay board can be found in the "Options" chapter.
Setting for "External lamp”
According to the "Charging lights" section of the "Options" chapter, suitable ex-
ternal indicators can be connected in order to visualize the state of charge or the
operating status of the battery charger. The following settings are available:
-
Normal (conventional external indicators)
-
RGB (LED strips)