Status codes in the event of a CAN fault (battery)
No. Cause / Remedy
(51) Battery not responding
(52) Battery data cannot be requested
(53) Battery voltage not supported
(54) Communication fault
(55) Battery fault
(56) Battery does not switch on
(57) Message time limit exceeded
(58) Registration failed
Status codes in the event of a gateway fault
No. Cause / Remedy
(101) Setting CAN Connect is active and no CAN connection to the gateway
could be established for at least 2 minutes.
(102) No gateway connection to the back-end.
Status codes in the event of a charging error
No. Cause / Remedy
(31) Timeout in I1 phase
(32) Timeout in U1 phase
(33) Battery overvoltage in the I2 phase
(34) Ah limit exceed
(35) Timeout in I2 phase
(36) Target voltage in I2 phase not reached (with format characteristic only)
(37) Problem with RI charge
(38) Set charging time cannot be reached
(39) Timeout in RI charge
Status codes in the event of a fault in the primary circuit
No. Cause / Remedy
(500) Module 1 (top) temperature sensor faulty
(501) Module 2 (bottom) temperature sensor faulty
(502) PCB temperature sensor faulty
(503) Primary overtemperature
(504) Fan blocked/faulty
53
EN

Table of Contents

Other manuals for Fronius Selectiva 3.0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Selectiva 3.0 and is the answer not in the manual?

Fronius Selectiva 3.0 Specifications

General IconGeneral
BrandFronius
ModelSelectiva 3.0
CategoryBattery Charger
LanguageEnglish

Related product manuals