EasyManua.ls Logo

Frontgate FG388LP-SD - Ignition and Regulator Problems; Motor and Noise Troubleshooting

Frontgate FG388LP-SD
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TROUBLESHOOTING
23
PROBLEM SOLUTION
When I light the grill it does not
flame immediately.
Make sure you have the gas turned ON.
Make sure it has a spark while you are trying
to ignite the burner.
Push the knob in for approximately 2-3 seconds
before turning to ignite the grill.
Make sure your burner is clean.
Rotisserie burner will not light when the
control knob igniter is turned.
Check to see if debris is blocking
the electrodes.
Check to see if there is a spark.If no spark is
seen THEN:
- Check the battery located inside the Battery
Box housing behind the button. Press and
turn counter-clockwise.
- Check for loose wire connection.
- Gently bend the electrode wire closer to the
burner until a spark is seen to jump from the
igniter to the burner when turning the Control
Knob igniter.
- Does the infrared back burner light when
attempting to match light? If not, check to
see if the gas is turned "ON".
Regulator makes a loud noise (not a low
level hum).
Vent hose on the regulator may be plugged or
regulator may be faulty
.
If Liquid Propane: Disconnect regulator and
re-install.
Ensure the vent hole on the regulator is not
obstructed. Clear the hole, close the gas control
valves. Wait five minutes and re-start.
Check your flames for proper performance if
the flames are not correct replace regulator.
Rotisserie motor will not turn.
Check the voltage at the outlet.
If an extension cord is required, ensure it is a
16 gauge grounded cord.
Ensure the ON/OFF switch is ON.
Ensure the load does not exceed the 40 lb.
operational capacity
.
Ensure the spit is fully inserted into the motor.
Ensure there is no encumbrance or drag.
continued