Calibrate fryer recovery time (continued)
©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2009 Page 2 of 2
Frymaster Fryer Model BIELA14 and BIGLA30 – LOV Monthly
FR 3 M1
4
Adjust fryer, if necessary.
If the fryer’s recovery time is
not acceptable, check the fol-
lowing items on the fryer. If
you find any problems, cor-
rect them as described.
For electric fryers only, con-
firm that the large power plug
is properly plugged in. Adjust
as necessary.
For gas fryers only, check the
seal angle, gravity blade, and
standoff. Adjust their place-
ment if necessary.
For gas fryers only, check the
air flow and combustion air
blower. Adjust as necessary.
For gas fryers only, check the
condition of the radiant burn-
ers.
Refer to trouble shooting
guide in Operators manual.
5
Check recovery time again.
If Recovery Time is not
achieved in the proper time,
call the Frymaster Service
Hotline for assistance at 1-
800-551-8633.
6
Recalibrate all remaining
fryers.
Repeat steps 1 through 5 for
all remaining fryers.