Parameter Values range/ Default setting/ Comments System
types
Code
level
Loaded power
output
Informs the ICT of the compressor's
maximum power consumption.
Value range: 0 – 9999 kW
Default setting: 0 kW
All Customer
Idling power
output
Informs the ICT of the compressor's power
consumption when idling.
Value range: 0 – 9999 kW
Default setting: 0 kW
All Customer
4.11
SD card
All functions with access to the SD card can be found in this menu. A corresponding card
must be inserted in order to use them.
4.11.1
Saving parameters
The current set of parameters is written to the SD card. An SD card without write
protection must be inserted.
Caution: If data has already been saved on the inserted SD card, this is overwritten and
therefore permanently lost.
A set of parameters saved with this function can be read again using the "Load
parameters" function. It doesn't matter which control system was used to save the data. A
set of data can therefore be transferred to any number of control systems (with the same
software version).
4.11.2
Loading parameters
This function can be used to read a set of parameters from the SD card. An SD card
containing the file "ICTParam.par" must be inserted.
Before the data is actually loaded, the storage date and system type of the set of data
appear. Please check for plausibility first!
Caution: When the data from the SD card is loaded, all current control system settings are
overwritten and therefore permanently lost.