EasyManua.ls Logo

Fuji Electric FJ Series - AC Magnetic Contactor Dimensions & Wiring

Fuji Electric FJ Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
112(Mounting rail height: 15)
*1
*1
*2
*2
Coil terminal
M3.5
Auxiliary
terminal
M3.5
Main terminal
M6
Mounting hole
2-M4
Panel drilling
Wiring diagrams
Mounting dimension: mounting according to (1) or (2)
(1)…(55)~60×90
(2)…(55)~60×90
Mount it using the 2 holes on the diagonal line.
14.5
10.5
13138
81
43 23
(78)
53
7.7
28
91(Mounting rail height: 15)
81
61
8.5
*1
*2
2049
*1
35
60
34
1
2
Coil terminal
M3.5
Auxiliary terminal
M3.5
Main terminal
M4
Mounting hole
2-M4
Panel drilling
(48~)52
18.5(
~20.5)
Auxiliary
contact
Wiring diagrams
1NO
(1a)
1NC
(1b)
14
135/L33/L21/L1
2/T1 4/T2 6/T3
A2A1
1/L1
2/T1
A1 A2
6/T34/T2
3/L2 5/L3 21
22
Mounting dimension: mounting according to (1) or (2)
(1)…35×60
(2)…34×(48~)52
Mount it using the 2 holes on the diagonal line.
7.7
6
Coil terminal
M3.5
Auxiliary terminal
M3.5
Main terminal
M3.5
61(Mounting rail height: 15)
36
49
48
31
45
8.7
Mount it using the 2 holes on the diagonal line.
Auxiliary
contact
Wiring diagrams
1NO
(1a)
1NC
(1b)
14
13 5/L33/L21/L1
2/T1 4/T2 6/T3
A2A1
1/L1
2/T1
A1 A2
6/T34/T2
3/L2 5/L3 21
22
Mounting hole
2-M4
40
35
Panel drilling
Mass: 0.14kg
Mass: 0.33kg
*1 For front mounting aux. contact blocks mounted.
*2 For two side mounting aux. contact blocks mounted.
*1 For front mounting aux. contact blocks mounted.
*2 For two side mounting aux. contact blocks mounted.
*1 For front mounting aux. contact blocks mounted.
*2 For two side mounting aux. contact blocks mounted.
*1 For front mounting aux. contact blocks mounted.
*2 For two side mounting aux. contact blocks mounted.
90 (Mounting rail height: 15)
(28)
80
7.7
10
61
43
23
8.5
(68)
81
43
14.5
18.5(~20.5)
35
(48~)52
60
34
Coil terminal
M3.5
Auxiliary terminal
M3.5
Main terminal
M3.5
Mounting hole
2-M4
Panel drilling
Mounting dimension: mounting according to (1) or (2)
(1)…35×60
(2)…34×(48~)52
Mount it using the 2 holes on the diagonal line.
Auxiliary
contact
Wiring diagrams
1NO
(1a)
1NC
(1b)
22
215/L33/L2
4/T2 6/T3
A2A1
2/T1
1/L1
A1 A2
6/T34/T2
2/T1
1/L1 3/L2 5/L3 13
14
1
2
*2
*1
*1
Mass: 0.35kg
Mass: 0.54kg
Mass: 0.97kg
z Magnetic Contactor (AC operated)
FJ-B06
FJ-B09
FJ-B12
35mm
FJ-B18
35mm
FJ-B25
FJ-B32
35mm
FJ-B40
FJ-B50
FJ-B65
35mm
FJ-B80
FJ-B95
35mm
106 (Mounting rail height: 15)
*1
*2
*2
*1
Coil terminal
M3.5
Auxiliary terminal
M3.5
Main terminal
M5
Mounting hole
2-M4
Panel drilling
Wiring diagrams
Mounting dimension: mounting according to (1) or (2)
(1)…45×75
(2)…45(38~46)×52
Mount it using the 2 holes on the diagonal line.
Dimensions and wiring diagrams
Information subject to change without notice
16
Contactors and Thermal Overload Relays