EasyManua.ls Logo

FujiFilm 700 Series - User Manual

FujiFilm 700 Series
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
English
Endoscopes
OPERATION MANUAL
Introduction
1
Precautions
Product Overview
2
Workflow
3
Preparation and Inspection
4
How to Use
5
Troubleshooting
6
Service
7
Appendix
This Operation Manual provides details on how to
prepare and operate the endoscope and describes
cautions to be observed. Please read this manual
thoroughly before operating the endoscope.
After reading this manual, store it nearby the
endoscope so that you can review it whenever
necessary.
Lower Gastrointestinal Endoscopes
EC-760Z-V/M
EC-760Z-V/L
897N201625
897N201625.book i ージ 019年2月18日 月曜日 午前9時2

Table of Contents

Questions and Answers

  • H
    heathermillerSep 9, 2025
    What to do if suction valve does not return to the original position in FujiFilm 700?
    • C
      Craig HodgesSep 9, 2025
      If the suction valve does not return to its original position in your FujiFilm Medical Equipment, it may be due to solid materials or thick fluids adhering to it, or the valve may be damaged. Detach the suction tube from the suction unit, detach the suction valve, and replace it with a new reprocessed suction valve.
  • C
    Craig VargasAug 23, 2025
    What to do if there is no air/water supply in my FujiFilm 700?
    • A
      antonio54Aug 23, 2025
      If there is no air/water supply in your FujiFilm Medical Equipment, consider the following: * Check if the air pump in the light source is turned off and select an appropriate level (High, Middle, or Low). * Ensure the air/water valve is not faulty; replace it if needed. * Press the air/water valve firmly. * Make sure the water tank cap is tightly closed. * Verify the water level is not overfilled (should be around 80% of capacity). * Ensure the water tank is filled with sterile water and properly connected. * Check for any clogs in the air/water nozzle or channel and reprocess if necessary.
  • C
    Charles WilliamsAug 25, 2025
    What to do if my FujiFilm 700 image is dark?
    • B
      bberryAug 26, 2025
      If the image appears dark on your FujiFilm Medical Equipment, try the following: Ensure the endoscope is correctly connected to the light source. Adjust the brightness level to around 0. Change the iris mode to “AVE.” Clean the light guide cover glass of the scope connector, the objective lens, or the light guides using soft, sterile gauze moistened with alcohol to remove any moisture or foreign matter.
  • P
    Patrick RogersAug 26, 2025
    Why is the suction weak on my FujiFilm Medical Equipment?
    • M
      Ms. Leah Franklin PhDAug 27, 2025
      If you're experiencing low suction volume with your FujiFilm Medical Equipment, consider these possible causes: The suction valve or forceps valve may be damaged and need replacement. Ensure the suction tube and forceps valve are properly attached. Check if the water jet inlet cap is open and close it to block the water jet inlet.
  • M
    Michael MccarthyAug 27, 2025
    What causes distorted images on FujiFilm Medical Equipment and how to fix it?
    • K
      Kayla JacksonAug 28, 2025
      Distorted images on your FujiFilm Medical Equipment can be caused by high-frequency interference. To fix it, stop the power supply to the high-frequency endotherapy device to restore image output. Also, make sure that the endoscope is properly connected to the light source.
  • B
    Brenda TaylorAug 29, 2025
    Why air/water supply does not stop on FujiFilm 700?
    • K
      Keith FrancisAug 29, 2025
      If the air/water supply on your FujiFilm Medical Equipment doesn't stop, it could be due to foreign matter adhering to the air/water valve, or the valve may be damaged or degraded. Reprocess the air/water valve or replace it with a new one.
  • N
    Nicholas ClarkSep 18, 2025
    Why bending section cannot return to neutral position on FujiFilm 700?
    • Y
      ygarnerSep 18, 2025
      If the bending section of your FujiFilm Medical Equipment cannot return to the neutral position, the up/down and left/right angulation knobs may be locked. Turn the up/down and left/right angulation locks in the direction of F (Free) until they stop to unlock the knobs.
  • T
    Tammy BlackSep 18, 2025
    The optical zoom function does not work on my FujiFilm Medical Equipment, what should I do?
    • D
      Diane ChanSep 22, 2025
      If the optical zoom function does not work on your FujiFilm Medical Equipment, the “Zoom In” or “Zoom Out” function may not be assigned to the scope switch. Assign the “Zoom In” or “Zoom Out” function to the scope switch.
  • M
    Melissa FosterSep 8, 2025
    What to do if sterile water does not come out of water jet nozzle on FujiFilm 700 Medical Equipment?
    • L
      luisloveSep 8, 2025
      If no sterile water comes out of the water jet nozzle on your FujiFilm Medical Equipment, check if the J tube or water jet channel is clogged with foreign matter and reprocess it. Ensure the J tube is connected and not damaged; replace if necessary. Also, re-check all components of the water pump per manufacturer’s instructions.
  • L
    Logan MarshallSep 4, 2025
    Why is the operation of the air/water valve heavy on my FujiFilm 700 Medical Equipment?
    • N
      Nicole AcostaSep 4, 2025
      If the operation of the air/water valve feels heavy on your FujiFilm Medical Equipment, it could be due to increased friction resistance between the air/water valve and the air/water valve cylinder. Detach the air/water valve and moisten the rubber seal with sterile water.

Summary

Introduction

About This Manual

Provides necessary information for using the product, including equipment overview, operation procedures, and precautions.

Endoscope Operation Manuals

Instructions for managing and storing the Operation and Reprocessing Manuals together as a set.

Precautions

Intended Use

Specifies the intended use of FUJIFILM Endoscope Models EC-760Z-V/M and EC-760Z-V/L for observation, diagnosis, and treatment.

Applicability of Endoscopy and Endoscopic Treatment

Advises on exercising proper clinical judgment for the applicability of endoscopy and treatment.

User Qualifications

Outlines responsibilities for use/maintenance and intended medical professional users.

Prohibition of Modification and Improper Repair

Prohibits modification, disassembly, or unauthorized repairs to prevent liability for defects.

Reprocessing Before the First Use;Reprocessing and Storage After Use

Details reprocessing requirements before first use, after servicing, use, and storage.

For Safe Operation

Emphasizes preparing spare endoscopes for unexpected events and ensuring readiness for procedures.

Maintenance

Advises on regular checks by service personnel due to component deterioration from use.

Symbols

Explains the safety signs used throughout the product manual.

Precautions for Transportation

Provides guidelines for safely carrying and transporting the endoscope to prevent damage or infection.

Precautions Against Electric Shock

Advises on proper connection to protective earth receptacles and avoiding incompatible equipment.

Electromagnetic Compatibility (EMC)

Details precautions to prevent electromagnetic interference when using the product.

General Warnings and Cautions

Covers essential safety warnings and cautions for handling the endoscope and accessories.

Precautions for Equipment Used in Combination

Warns against using unspecified related equipment to ensure safety and functionality.

Product Overview

Checking Package Contents

Instructions to check endoscope and components against package items for damage or missing parts.

Nomenclature and Functions of Endoscope

Details the names and functions of various parts of the endoscope.

Nomenclature and Functions of Distal End of Endoscope

Describes the components and their functions at the distal end of the endoscope.

Flexibility Adjustment Mechanism

Explains how to adjust the flexibility of the insertion tube using the mechanism.

Optical Zoom Function

Describes the optical zoom function for magnifying images and adjusting focus simultaneously.

Location of Each Label

Shows the positions of labels affixed to the product for identification.

System Configuration

Lists recommended combinations of related equipment for system setup.

Workflow

When Using Standard Functions

Illustrates the workflow of using standard functions with relevant section references.

Preparation and Inspection

Preparation of the Equipment

Details the preparation of the endoscope, accessories, and related equipment before use.

Transporting Endoscope

Explains the procedure for transporting a reprocessed endoscope safely.

Inspecting Endoscope

Provides steps for visually and manually inspecting the endoscope for abnormalities before use.

Inspecting and Attaching Accessories

Guides on inspecting and attaching key accessories like forceps valve, suction valve, etc.

Preparing Related Equipment

Covers preparation steps for essential related equipment and system setup.

Connecting Endoscope to Light Source and Related Equipment

Details the procedures for connecting the endoscope to the light source and other equipment.

Inspecting Functions Used in Combination with Related Equipment

Describes how to inspect key functions when using the endoscope with related equipment.

How to Use

Preparation

Outlines the necessary preparations before commencing the procedure.

Insertion and Observation

Details procedures for inserting the endoscope and observing images, including mechanism use.

Using Water Jet Function

Explains how to operate the water jet function for cleaning or spraying an area.

Using Optical Zoom Function

Describes how to use the optical zoom function to enlarge or reduce the image.

Injecting Fluids from Instrument Channel Inlet

Provides steps for filling a syringe and injecting fluids through the instrument channel.

Treatment

Covers procedures for performing treatments, including using endotherapy devices and high-frequency treatments.

Endoscope Withdrawal

Details the correct procedures for withdrawing the endoscope safely after use.

Reprocessing Endoscope

Instructs on reprocessing the endoscope and accessories as per the Reprocessing Manual.

Troubleshooting

Troubleshooting Common Problems

Lists common problems and their remedies for displayed images, scope switches, and bending sections.

Withdrawal of Endoscope with Abnormality

Provides procedures for withdrawing the endoscope when abnormalities occur during a procedure.

Handling of Endoscope with Abnormality

Details specific handling procedures for endoscopes with abnormalities, like suction valve issues.

Returning Endoscope for Repair

Guides on providing details and returning the endoscope for evaluation or repair.

Service

Service Information

General advice to check the manual or contact a dealer if the product is not working.

After-Sales Service and Warranty

Details warranty periods, void conditions, and contact information for repairs.

Appendix

Main Specifications Overview

Provides key specifications including electrical safety, EMC standards, and applied parts.

Environmental and Durability Specifications

Outlines operating, transport, storage environments, and the term of validity.

Accessory List

Lists accessories with limited life expectancy that require replacement upon wear.

Related Equipment Used in Combination

Lists compatible processors, light sources, tanks, pumps, and other related equipment.

Electromagnetic Compatibility (EMC) Information

Provides detailed information on emission and immunity compliance according to EMC standards.

Disposal of Electric and Electronic Equipment

Instructs on proper disposal of electrical and electronic equipment to prevent environmental harm.

FujiFilm 700 Series Specifications

General IconGeneral
BrandFujiFilm
Model700 Series
CategoryMedical Equipment
LanguageEnglish