1-5. Compressor frequency limitation by outdoor temperature
The minimum compressor frequency is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
38°C
E zone
19°C
D zone
10°C
C zone
B zone
A zone
0°C
-10°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOHG09KVCBN
A zone 31 rps
B zone 31 rps
C zone 31 rps
D zone 1 rps
E zone 1 rps
F zone 22 rps
AOHG12KVCBN
AOHG14KVCBN
A zone 26 rps
B zone 26 rps
C zone 26 rps
D zone 1 rps
E zone 1 rps
F zone 22 rps
Heating mode
F zone
19°C
E zone
5°C
D zone
0°C
C zone
B zone
A zone
-15°C
-25°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOHG09KVCBN
AOHG12KVCBN
AOHG14KVCBN
A zone 39 rps
B zone 39 rps
C zone 17 rps
D zone 10 rps
E zone 1 rps
F zone 1 rps
1-5. Compressor frequency limitation by outdoor temperature - (04-6) - 1. Compressor frequency control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AGHG12KVCB and is the answer not in the manual?

Fujitsu AGHG12KVCB Specifications

General IconGeneral
BrandFujitsu
ModelAGHG12KVCB
CategoryAir Conditioner
LanguageEnglish

Related product manuals