Provides front, side, and top views with dimensions for AGYG09KVCA, AGYG12KVCA, and AGYG14KVCA indoor units.
Illustrates required clearances around the indoor unit for proper ventilation and installation.
Detailed wiring diagram for indoor unit components, including PCB connections and external interfaces.
Presents cooling capacity data based on various indoor and outdoor temperature conditions.
Presents heating capacity data based on various indoor and outdoor temperature conditions.
Charts showing air velocity patterns for different airflow directions and fan speeds.
Details airflow rates in m³/h, l/s, and CFM for cooling and heating at various fan speeds.
Sound pressure level curves as a function of octave band center frequency for different modes.
Specifies the location and distance for measuring sound pressure levels of the indoor unit.
Details on connecting external signals for operation/stop and thermostat control via CN14/CN15.
Information on output signals for status indication like operation, error, or fan status via CN20-CN23.
Examples of combining external inputs and outputs with function settings for various operations.
Detailed explanation of control functions like Operation/Stop modes and Forced thermostat off.
Introduction to the wireless remote controller, its buttons, display panel, and indicators.
Details the physical dimensions and weight of the remote controller and its holder.
Procedure for adjusting function settings using the wireless remote controller.
Comprehensive list of adjustable function numbers and their descriptions.
Procedure for assigning custom codes to interconnect air conditioners and remote controllers.
List and quantity of standard accessories included with the indoor unit models.
Overview of various optional wired and simple remote controllers available for indoor units.
Details on optional connection kits, adapters, and converters for indoor units.
Technical specifications for AOYG09KVCA, AOYG12KVCA, and AOYG14KVCA outdoor units.
Physical dimensions and installation views for AOYG09KVCA and AOYG12KVCA outdoor units.
Physical dimensions and installation views for the AOYG14KVCA outdoor unit.
Guidelines for required clearances for single and multiple outdoor unit installations.
Diagram illustrating refrigerant flow and components for AOYG09KVCA and AOYG12KVCA outdoor units.
Diagram illustrating refrigerant flow and components for the AOYG14KVCA outdoor unit.
Electrical wiring diagrams for AOYG09KVCA and AOYG12KVCA outdoor units.
Electrical wiring diagram for the AOYG14KVCA outdoor unit.
Capacity compensation rates based on pipe length and height difference for specific models.
Capacity compensation rates for AOYG14KVCA by pipe length and height difference.
Guidance on calculating additional refrigerant charge for specific pipe lengths.
Refrigerant charge calculation for AOYG14KVCA based on total pipe length.
Airflow rates (m³/h, l/s, CFM) for cooling and heating modes.
Airflow rates (m³/h, l/s, CFM) for cooling and heating modes.
Airflow rates (m³/h, l/s, CFM) for cooling and heating modes.
Sound pressure level curves by octave band for cooling and heating modes.
Specifies the location and distance for measuring sound pressure levels of the outdoor unit.
Electrical parameters including voltage, frequency, current, and wiring specifications.
List of standard accessories included with the outdoor unit models.