EasyManua.ls Logo

Fujitsu AGYG09KVCA - Safety Devices

Fujitsu AGYG09KVCA
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11. Safety devices
Type of
protection
Protection form
Model
AOYG09KVCA AOYG12KVCA AOYG14KVCA
Circuit protection
Current fuse
(PCB*)
250 V, 20 A 250 V, 25 A
250 V, 5 A 250 V, 5 A
250 V, 3.15 A 250 V, 3.15 A
Fan motor
protection
Thermal
protection
program
Activate
100±15 °C
Fan motor stop
125±10 °C
Fan motor stop
Reset
95±10 °C
Fan motor restart
120±10 °C
Fan motor restart
Compressor
protection
Thermal
protection
program
(Discharge
temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
*PCB: Printed Circuit Board