1. Specifications
Type Inverter heat pump
Model name AOYG09KVCA AOYG12KVCA AOYG14KVCA
Power supply 230 V ~ 50 Hz
Available voltage range 198—264 V
Starting current A 4.1 5.7 6.2
Fan
Airflow rate
Cooling
m
3
/h
1,530 1,530 2,210
Heating 1,510 1,510 2,100
Type × Q'ty Propeller × 1
Motor output W 23
Sound pressure level *1
Cooling
dB (A)
43 45 51
Heating 47 51 50
Sound power level
Cooling
dB (A)
58 61 63
Heating 61 64 63
Heat exchanger type
Dimensions
(H × W × D)
mm
Main1: 504 × 881 × 18.19
Main2: 504 × 851 × 18.19
Fin pitch 1.3
Rows × Stages 2 × 24 2 × 28
Pipe type Copper
Fin type
Type (Material) Aluminium
Surface treatment PC Fin
Compressor
Type × Q'ty DC ROTARY DC TWIN ROTARY
Motor output W 900 925
Refrigerant
Type (Global warming potential) R32 (675)
Charge g 850 940
Refrigerant oil
Type RB68A RmM68AF
Amount
cm
3
340 400
Enclosure
Material Steel sheet
Color
BEIGE
Dimensions
(H × W × D)
Net
mm
542 × 799 × 290 632 × 799 × 290
Gross 602 × 940 × 375 692 × 940 × 375
Weight
Net
kg
31 38
Gross 35 42
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas Ø 9.52 (Ø 3/8)
Method Flare
Pre-charge length
m
15
Max.length 20
Max. height difference 15
Operation range
Cooling
°C
-10 to 46
Heating -15 to 24
Drain hose
Material PP
Size mm φ13.0(I.D.), φ16.0 to φ16.8(O.D.)
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length: 5 m, Height difference: 0 m.
Protective function might work when using it outside the operation range.
*1: Sound pressure level
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.