Model: AGYG14KVCA
Operation mode
Fan mode
(Upper/Lower)
Speed (rpm)
Upper & Lower air flow
mode
Upper air flow mode
Heating
POWERFUL 1,440/1,230 1,440/ —
HIGH 1,330/1,120 1,370/ —
MED+ 1,100/930 1,130/ —
MED 1,100/930 1,130/ —
LOW- 860/730 890/ —
QUIET 660/560 680/ —
Cool air prevention 660/560 680/ —
S-LOW 660/560 680/ —
Cooling/Fan
POWERFUL 1,440/1,230 1,440/ —
HIGH 1,330/1,120 1,370/ —
MED 1,100/930 1,130/ —
LOW 890/750 890/ —
QUIET 660/560 680/ —
Soft quiet
570/480*
1
630/ —*
1
S-LOW
660/560*
2
680/ —*
2
Dry
X zone: — / —
J zone: — / —
X zone: 680/ —
J zone: 680/ —
*1: Fan mode only
*2: Cooling mode only
¢ Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
¢ Cooling operation
Switch the airflow AUTO, and indoor fan motor will run according to room temperature, as below.
On the other hand, if switched in HIGH—QUIET, indoor motor will run at a constant airflow of COOL
operation modes QUIET, LOW, MED, HIGH as shown in “Fan speed” above.
Airflow change over (Cooling: Auto)
When room
temperature rises
When room
temperature drops
Tr - Ts ≥ 2°C
HIGH mode
MED mode
LOW mode
2°C > Tr - Ts ≥ 1°C
1°C > Tr - Ts
Tr - Ts ≥ 2.5°C
2.5
°C > Tr - Ts ≥ 1.5°C
1.5°C > Tr - Ts
3-1. Indoor fan control