3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢ Fan speed
Indoor fan speed is defined as below.
Models: AGYG09KVCA and AGYG12KVCA
Operation mode
Fan mode
(Upper/Lower)
Speed (rpm)
Upper & Lower air flow
mode
Upper air flow mode
Heating
POWERFUL 1,350/1,150 1,350/ —
HIGH 1,240/1,040 1,280/ —
MED+ 1,040/880 1,080/ —
MED 1,040/880 1,080/ —
LOW- 840/700 870/ —
QUIET 660/560 680/ —
Cool air prevention 660/560 680/ —
S-LOW 660/560 680/ —
Cooling/Fan
POWERFUL 1,300/1,100 1,300/ —
HIGH 1,190/1,000 1,230/ —
MED 1,000/850 1,030/ —
LOW 820/690 850/ —
QUIET 660/560 680/ —
Soft quiet
570/480*
1
630/ —*
1
S-LOW
660/560*
2
680/ —*
2
Dry
X zone: — / —
J zone: — / —
X zone: 680/ —
J zone: 680/ —
*1: Fan mode only
*2: Cooling mode only
3-1. Indoor fan control - (04-10) - 3. Fan control