WARNING
Disconnect switch and for over current protection given in the table below is to be
installed between the indoor unit and the outdoor unit.
Disconnect switch
15A
CAUTION
Be sure to refer the above diagram and do correct eld wiring.
Wrong wiring causes malfunction of the unit.
Check local electrical codes and also any specic wiring instructions or limitation.
Outdoor unit5. 5.
(1) Service cover removal
• Remove the two mounting screws.
• Remove the service cover by pushing downwards.
(2) Fasten the power supply cord and the connection cord to the conduit holder using the
lock nut.
(Open the knock out holes with the tool so as not to transform conduit plate if
necessary.)
(3) Connect the power supply cord and the connection cord to terminal.
(4) Fasten the power supply cord and connection cord with cord clamp.
Lock nut
Conduit plate
Power cord
Knockout hole
Connection cord