9.3. Checklist
Check description Check method Criteria
(1) High and low pressure values
are normal.
Check it with a pres-
sure gauge.
Cooling: low pressure ap-
prox. 0.8 MPa
Heating: high pressure
approx.
3.0 MPa
(2) Drain water is discharged
smoothly through the drain
hose.
Check it by pouring
water.
―
(3) Indoor and outdoor unit fans
are operating.
Check them visually. ―
(4) Compressor operates after
the indoor unit operates.
Check the operating
sound.
―
(5) Difference between inlet and
outlet temperatures is normal.
Measure the inlet and
outlet temperatures.
Temperature difference
10 degrees
(6) Error is not displayed.
Check the 7-segment
display.
Error blinking or no error
code display
10. LED STATUS
You can determine the operating status by the lighting up and blinking of the LED display.
Check the status using the table below.
10.1. Normal operation codes
Mode CODE DESCRIPTION
Operation
CL
Cooling
Ht
Heating
or
During oil recovery operation
dF
During defrosting operation
PC
During power saving operation
Ln
During low noise operation
Sn
During setting of snowfall mode
10.2. Error codes
Mode Code Description
Communication error
E 1 3. 1 Communication error between outdoor units
E 1 4. 1 Outdoor unit network communication 1 error
E 1 4. 2 Outdoor unit network communication 2 error
E 1 4. 5 The number of indoor unit shortage
Function setting error
E 2 8. 1 Auto address setting error
E 2 8. 4 Signal amplifier auto address error
Indoor unit actuator
error
E 5 U. 1 Indoor unit miscellaneous error
Outdoor unit PCB/
electrical component/
switch error
E 6 1. 5
Outdoor unit reverse phase, missing phase wire
error
E 6 2. 3 Outdoor unit EEPROM access error
E 6 2. 6 Outdoor unit inverters communication error
E 6 2. 8 Outdoor unit EEPROM data corruption error
E 6 3. 1 Outdoor unit inverter error
E 6 7. 2
Outdoor unit inverter PCB power short interruption
error
E 6 8. 2
Outdoor unit rush current limiting resister temp. rise
error (protective operation)
E 6 9. 1
Outdoor unit transmission PCB parallel communi-
cation error
Outdoor unit sensor
error
E 7 1. 1 Outdoor unit discharge thermistor 1 error
E 7 2. 1 Outdoor unit compressor temp. sensor 1 error
E 7 3. 4 Outdoor unit heat ex. 1 gas temp. sensor error
E 7 3. 5 Outdoor unit heat ex. 1 liquid temp. sensor error
E 7 3. 6 Outdoor unit heat ex. 2 gas temp. sensor error
E 7 3. 7 Outdoor unit heat ex. 2 liquid temp. sensor error
E 7 4. 1 Outside air thermistor error
E 7 5. 1 Outdoor unit suction gas thermistor error
E 7 7. 1 Outdoor unit heat sink thermistor error
E 8 2. 2
Outdoor unit sub-cool heat ex. gas outlet thermis-
tor error
E 8 3. 1 Outdoor unit liquid pipe thermistor 1 error
E 8 3. 2 Outdoor unit liquid pipe thermistor 2 error
E 8 4. 1
Outdoor unit current sensor 1 error (permanent
stop)
E 8 6. 1 Outdoor unit discharge pressure sensor error
E 8 6. 3 Outdoor unit suction pressure sensor error
E 8 6. 4 Outdoor unit high pressure switch 1 error
Mode Code Description
Outdoor unit actuator
error
E 9 3. 1 Outdoor unit inverter compressor start up error
E 9 4. 1 Outdoor unit trip detection
E 9 5. 5
Outdoor unit compressor motor loss of synchronization
E 9 7. 1 Outdoor unit fan motor lock error
E 9 7. 5
Outdoor unit fan motor temperature error (protec-
tive action)
E 9 7. 9 Outdoor unit fan motor driver error
E 9 A. 1 Outdoor unit coil 1 (expansion valve 1) error
E 9 A. 2 Outdoor unit coil 2 (expansion valve 2) error
E 9 A. 3 Outdoor unit coil 3 (expansion valve 3) error
E 9 U. 2 Outdoor subordinate unit error
Refrigerant system
error
E A 1. 1 Outdoor unit discharge temperature 1 error
E A 3. 1 Outdoor unit compressor 1 temperature error
E A 4. 1 Outdoor unit high pressure error
E A 4. 2 Outdoor unit high pressure protection 1
E A 5. 1 Outdoor unit low pressure error
E A 6. 3 Outdoor heat exchanger 1 gas temperature error
E A 6. 4 Outdoor heat exchanger 2 gas temperature error
E A C. 4 Outdoor unit heat sink temperature error
㪃
㪃
㫋㪑
㪣㪑
㪎㪑
㪟
㪡㪑
㪍㪑
㪚
㪝
㪻㪑 㫅㪑 㫆
㫉㪑
㪃
㪐㪑
㪧
㪬㪑
㪪㪑
㪏㪑
㪃
㪌㪑㪊㪑 㪋
㪈㪑 㪉㪑
㪇㪑
7 segment LED indicator:
11. INFORMATION
Main contents of label
Item Detail
(1) Model name Model name
(2) Serial number Serial number
(3) Electric characteristics Phase, rated voltage, and frequency
(4) Weight Product weight
(5) Capacity
Cooling/heating capacity under cooling/heating
condition (refer to item 15)
(6) Current
Electric current during cooling/heating operation
under cooling/heating condition
(refer to item 15)
(7) Input power
Input during cooling/heating operation under cool-
ing/heating condition (refer to item 15)
(8) Max. Current
Maximum electric current
(Test condition: IEC60335-2-40)
(9) Air circulation Air circulation
(10) Noise level Noise level
(11) Refrigerant Refrigerant type and initial charging amount
(12) Max. pressure (HP/LP)
Means pressure of High Pressure side/Low Pres-
sure side
(13) Protection Protection level against dust and water
(14) Working temperature Working temperature
(15) Condition of cooling/heating
Dry-bulb temperature and wet-bulb temperature
under standard cooling/heating condition
(16) Condition of max. cooling
Dry-bulb temperature and wet-bulb temperature at
maximum electric current and input
(17) Manufacture year Manufacture year
(18) Origin Origin country
(19) Manufacturer
Manufacturer
FUJITSU GENERAL LIMITED
Address: 3-3-17, Suenaga, Takatsu-ku, Kawasaki
213-8502, Japan
Label
9378945708-02_IM_L9.indb 229378945708-02_IM_L9.indb 22 2022/1/20 15:34:392022/1/20 15:34:39