En-5
The following conditions may not be breakdowns so check again.
Symptom Items to check
See page
Doesn’t operate at all: Has there been a power failure?
—
Has a fuse blown out, or a circuit breaker been tripped?
—
Is the main power switch set to the OFF position?
—
Are you trying to engage in an operation different from the priority state?
2
Is it in standby state?
2
The operation mode cannot be
changed:
Are you trying to change to an operation different from the priority conditions?
2
Poor Cooling (or Heating)
performance:
Did you adjust the room temperature settings (thermostat) correctly?
—
Is the air fi lter dirty?
3
Are the air conditioner’s inlet port or outlet port blocked?
—
Is there a window or door open?
—
In the case of Cooling operation, is a window allowing bright sunlight to enter? (Close the curtains.)
—
In the case of Cooling operation, are there heating apparatus and computers inside the room, or are
there too many people in the room?
—
Is the fan speed set to low?
—
Set the temperature lower than
the room temperature and use it:
Temperature does not fall down well.
Temperature may not fall down depending on the room conditions.
(While high humidity or the room temperature is high.)
3
In following situations stop operation immediately and get in touch with authorized service personnel.
The problem cannot be solved even when the troubleshooting checks have been performed. ●
The OPERATION indicator lamp (green) is fl ashing very fast. ●
The wired remote controller or simple remote controller indicate Er (when connected). ●
It has burning smell. ●
SPECIFICATIONS
MODEL ASE07GACH ASE09GACH ASE12GACH ASE14GACH
POWER SOURCE 230 V ~ 50 Hz
AVAILABLE VOLTAGE RANGE 198 to 264 V
COOLING CAPACITY [kW] 2.2 2.8 3.6 4.5
HEATING CAPACITY [kW] 2.8 3.2 4.1 5.0
SOUND PRESSURE LEVEL
HIGH dB [A] 34 35 38 43
MED dB [A] 32 32 34 35
LOW dB [A] 30 30 30 30
DIMENSIONS & WEIGHT
HEIGHT [mm] 275
WIDTH [mm] 790
DEPTH [mm] 215
WEIGHT [kg] 9
MODEL ASA07GACH ASA09GACH ASA12GACH ASA14GACH
POWER SOURCE 230 V ~ 50 Hz
AVAILABLE VOLTAGE RANGE 198 to 264 V
COOLING CAPACITY [kW] 2.2 2.8 3.6 4.5
HEATING CAPACITY [kW] 2.8 3.2 4.1 5.0
SOUND PRESSURE LEVEL
HIGH dB [A] 35 36 39 44
MED dB [A] 33 33 35 37
LOW dB [A] 31 31 31 32
DIMENSIONS & WEIGHT
HEIGHT [mm] 275
WIDTH [mm] 790
DEPTH [mm] 215
WEIGHT [kg] 9
Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor unit. ●
According IEC 704-1 and ISO 3744.
9377772084-01_OM.indb 59377772084-01_OM.indb 5 2012-6-25 14:19:372012-6-25 14:19:37