4. INDOOR FAN CONTROL
1. FAN SPEED
Indoor fan speed is defined by operation mode and airflow mode.
In Economy operation and when operation mode is fan,
airflow is 1 step downs.
04-11
AMUG24LMAS AMUG30LMAS AMUG36LMAS AMUG48LMAS
High 800 870 1200 1640
Medium + - - - -
Medium 670 730 740 1020
Low 590 590 590 820
Quiet 310 310 490 590
Cool
air
prevention - - - -
S-low 300 300 480 480
High 800 870 1200 1640
Medium 670 730 740 1020
Low 590 590 590 820
Quiet 310 310 490 590
S-low 300 300 480 480
High 800 870 1200 1640
Medium 670 730 740 1020
Low 590 590 590 820
Quiet 310 310 490 590
Soft quiet 300 300 480 480
310
310 490 590Dry
Fan
Cooling
Heating
Airflow Volume (CFM)