EasyManuals Logo

Fujitsu AMUG24LMAS User Manual

Fujitsu AMUG24LMAS
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #138 background imageLoading...
Page #138 background image
17. VARIOUS PROTECTIONS
1. DISCHARGE GAS TEMPERATURE OVERRIDE PREVENTION CONTROL
Discharge gas thermosensor (discharge thermistor : Outdoor side)
detects discharge gas temperature.
AOUG36LMAS1
AOUG48LMAS1
AOU24RGLX
AOU30RGLX
When discharge temperature exceeds 219.2˚ F (104.0 ˚C),
compressor frequency is decreased 30rps,
and it continues to decrease 30 rps every 120 seconds
until temperature dips from 219.2˚F (104.0˚C)
When discharge temperature dips from 213.8˚F (101.0˚C),
control of compressor frequency is released.
When discharge temperature exceeds 230.0˚F (110.0˚C),
compressor stops and indoor unit LED starts blinking.
When discharge temperature exceeds 219.2˚F (104.0˚C),
compressor frequency is decreased 10rps,
and it continues to decrease 10 rps every 120 seconds
until temperature dips from 219.2˚F (104.0˚C)
When discharge temperature dips from 213.8˚F (101.0˚C),
control of compressor frequency is released.
When discharge temperature exceeds 230.0˚F (110.0˚C),
compressor stops and indoor unit LED starts blinking.
04-31

Table of Contents

Other manuals for Fujitsu AMUG24LMAS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AMUG24LMAS and is the answer not in the manual?

Fujitsu AMUG24LMAS Specifications

General IconGeneral
BrandFujitsu
ModelAMUG24LMAS
CategoryAir Conditioner
LanguageEnglish

Related product manuals