Limit of maximum speed based on outdoor temperature
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
E zone
F zone
10°C
0°C
12°C
2°C
Outdoor
temperature drops
Outdoor
temperature rises
Unit: rps
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
AUXG09KVLA
A zone 87 62 50 41
B zone 87 62 50 41
C zone 87 62 50 41
D zone 62 45 37 28
E zone 62 45 37 28
F zone 62 45 37 28
AUXG12KVLA
A zone 110 78 66 54
B zone 110 78 66 54
C zone 110 78 66 54
D zone 78 60 47 35
E zone 78 60 47 35
F zone 78 60 47 35
AUXG14KVLA
A zone 110 85 73 43
B zone 110 85 73 43
C zone 103 73 59 43
D zone 73 59 48 31
E zone 73 59 48 31
F zone 73 59 48 31
AUXG18KVLA
A zone 110 78 68 39
B zone 110 78 68 39
C zone 93 68 55 39
D zone 68 55 44 28
E zone 68 55 44 28
F zone 68 55 44 28
AUXG22KVLA
A zone 118 69 57 36
B zone 118 69 57 36
C zone 84 57 47 36
D zone 60 47 40 26
E zone 60 47 40 26
F zone 60 47 40 26
1-1. Cooling operation - (04-2) - 1. Compressor frequency control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Other manuals for Fujitsu AO G12KATA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AO G12KATA Series and is the answer not in the manual?

Fujitsu AO G12KATA Series Specifications

General IconGeneral
BrandFujitsu
ModelAO G12KATA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals